Troubleshooting
Problem
Cause
No electricity
Motor does not
run
Impeller is blocked
Windings burnt out
Pump is not fully sub-
merged in water
Motor runs but
Impeller damaged
little or no water
is drawn in
Rotor turns in the
wrong direction
Motor runs in-
Impeller is blocked
termittently
or is permanently
overloaded
Important Note
Technical Data
■ Model Suspended/Wall-mounted cartridge fi lter for set-up pools
■ Nominal voltage 12 VAC (50HZ)
■ Filter volume 2,8 l
■ Flow rate 1.700 l/h
■ Pool volume 8.000 l
■ Output (W) 20
■ Max. Watertemp. °C 35
■ Max. depth below water (m) 0,5
■ Transformer SG12 20,4 W, 230 V 50 Hz,
■ 12 VAC 1700MA 20,4 VA
Cleaning
Use conventional cleaning products. Do not use solvent-based or abra-
sive cleaning agents/tools, i.e. no hard sponges, brushes etc..
Storage
The product must be thoroughly dried after cleaning. After which, it is to
be stored in a dry location protected from frost.
Disposal
Disposing of packaging: The packaging material has been selected
in view of environmental concerns and disposability and is therefore
recyclable. The paper and cardboard can be recycled, as can the plastic
coverings.
Disposing of the product: Applicable in the European Union and other
European states with systems in place for collecting and sorting recycla-
ble materials. Dispose of the product in accordance with any laws and
regulations applicable at your place of residence.
Warranty conditions
The respective country's legal provisions for warranty conditions shall
apply accordingly.
Declaration of conformity (CE)
The EU declaration of conformity can be requested via the address
shown at the end of this manual.
Possible remedy
Check electricity source,
switch and wiring (have
them repaired or re-placed
by profes-sionals)
Dismantle pump
and clean
Replace pump
Raise water level
or lower pump
Clean fi lter insert
Switch transformer
off and then back
on again
Clean cartridge
and protect trans-
former against
overheating.