Wall-mounting the appliance and
levelling it
1
First remove the protective film from the back of the
appliance and, following installation, remove the
rest of the film.
2
When mounting the appliance, ensure that it
engages properly with the mounting supports.
3
If required, the appliance can be moved to the right
or to the left.
4
Firmly tighten the screws for the mounting
supports. Hold the bracket firmly when doing so.
5
If no duct is to be fitted, screw in the two locking
screws without the bracket.
Connecting the pipes
If the extractor hood is to be operated in air extraction
mode, the pipes must be connected. If the extractor
hood is to be operated in air recirculation mode, the
activated charcoal filters provided must be fitted.
Note: If an aluminium pipe is being used, smooth the
connection area beforehand.
Exhaust air pipe, dia. 150 mm (recommended size)
Fit the exhaust air pipe directly to the air-pipe connector
and seal the joint.
Exhaust air pipe, dia. 120 mm
1
Fit the reducing connector directly to the air-pipe
connector.
2
Attach the exhaust air pipe to the reducing connector.
3
Use suitable means to seal both joints.
Attaching the flue duct
If the extractor hood is to be operated in exhaust-air
mode, a flue duct must be fitted.
The flue duct does not need to be fitted for air-
recirculation mode.
m
Warning – Risk of injury!
From sharp edges during installation. Always wear
protective gloves while installing the appliance.
¨
©
m
Warning – Risk of electric shock!
Components inside the appliance may have sharp
edges. These may damage the connecting cable. Do not
kink or pinch the connecting cable during installation.
1
Separate the flue duct sections by removing the
adhesive tape.
2
Remove the pieces of protective film from both flue
duct sections.
3
Push one flue duct section into the other.
Notes
–
To prevent scratches, lay paper over the edges
of the outer flue duct section to protect the
surface.
–
The slots of the inner flue duct section point
downwards.
4
Place flue ducts sections on the appliance.
5
Slide the inner flue duct section upwards, attach it
to the left and right sides of the retaining bracket,
and then slide it down to engage it.
6
Screw the flue duct section to the sides of the
retaining bracket using two screws.
7
Clip the lower flue duct section in at the retaining
bracket. The connection cable must not be
ª
damaged.
Note: If an air-recirculation optional accessory has been
fitted and the extractor hood is to be operated without a
flue duct, the cable must be wound onto the connector.