Changing Settings - Webasto Cool Top RTE 16 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Remote controller
6
5
4
3
2
Fig. 02:
Remote controller
Legend Fig. 02:
1. ON-OFF button
2. Fan speed setting button
3. Temperature decrease button
4. Temperature increase button
5. Mode button
6. Transmit indication
Description
Press the "ON-OFF" button to switch the
Cool Top RTE 16 ON or OFF.
ON-OFF
When on, the display on the local control panel
shows the last set temperature.
With each push on the (+ / -) button you cycle
through the 6 different ventilation levels. The
display on the local control panel shows the se-
lected level.
Vent
If you press the ventilation (+ / -) button when
the Cool Top RTE 16 is off, you activate the ven-
tilation only mode.
Each push on one of the + / - buttons increases
or decreases the set temperature with 1 °C. The
minimum value is 17 °C, the maximum 32 °C.
The display on the local control panel shows the
selected temperature.
Pushing the "MODE" button you cycle through
the modes MIN, AUTO and MAX. The corre-
MODE
sponding icon on the local control panel shows
the selected mode.
Each time you press a button on the remote
controller the light comes on to show transmis-
sion activity.
Cool Top RTE 16
4.3
1
Press simultaneously the VENTILATION (+ / -) and the TEMPERA-
X
TURE (+) buttons to access the setting menu.
Scroll between the menus with the VENTILATION (+ / -) buttons.
X
Choose the desired values with the TEMPERATURE (+ / -) but-
X
tons.
– The values will be saved after a few moments without touch-
Exit from the menu by not touching any button.
X
Settings menu:
Item
P0
P1
P2
A3 Celsius and
A4 Offset
A5 Battery sav-
A5 settings:
A5
0
1
2
3
4
5
6
7
8
9

Changing settings

ATTENTION
Changing the standard settings must be carried out
only by qualified personnel. Any change performed
without the proper skills may cause damage to the
Cool Top RTE 16 and/or to the vehicle.
Changing settings can be done only with the system
off.
ing anything else.
Description
Timer
In MIN mode, the systems default setting is
(MIN mode)
6 hours of continuous operation. The default
value can be changed in this menu. The
choice range is between 1 and 99 hours.
Timer
In AUTO mode, the system's default setting
(AUTO
is 4 hours of continuous operation. The de-
mode)
fault value can be changed in this menu. The
choice range is between 1 and 99 hours.
Timer
In MAX mode, the system operates at its
(MAX mode)
max power for the preset time in minutes.
The choice range is between 1 and 99 min-
utes. The system switches to the AUTO
mode.
The systems default setting is Centigrade de-
Fahrenheit
grees. This menu allows you to change the
degrees
parameter to Fahrenheit degrees.
This refers to the temperature difference de-
tected by the probe and the temperature
shown on the display. This menu allows you
to change this value from -9 °C to +9 °C
with 1 °C increments.
The default setting is 21.5 VDC (Cut-out)
er value
and 24 VDC (Cut-in). This menu allows to
change these values based on the following
table.
24 VDC
A5
Cut-out
Cut-in
20
10
20,3
11
20,6
12
20,9
13
21,2
14
24,5
21,5
15 21,5 (default)
21,8
16
22,1
17
22,4
18
22,7
19
24 VDC
Cut-out
Cut-in
20
20,3
20,6
20,9
21,2
24 (default)
21,8
22,1
22,4
22,7
6

Publicidad

Tabla de contenido
loading

Tabla de contenido