15-amp reset button
power cord
Using Timer
The timer prevents overload by alternating power between both power units in the cart, providing charging to multiple laptops or devices during the day.
The power units plug into the outlets labeled 'A' or 'B'.
The timer control can be adjusted between 15-240 minutes. This is the number of minutes a power unit will be "hot" before the timer switches to the
other power unit. 15 minutes can be used as the default setting, but the time setting will depend on the laptop size, battery capacity, frequency of use,
and the time available for charging between uses. Lower minute settings should be used if the laptops are being used more frequently.
• To cycle charge both 'A' and 'B' sides, keep the cycle switch in the middle 'Cycle' position, then set the timer control to the desired cycling increment.
After the side 'A' time expires, the timer will activate side 'B' for the same period of time and will continue to cycle until the ON / OFF switch is set to
the OFF position.
• To manually-override the timer function, and charge the 'A' or 'B' side only, switch the cycle switch from the middle to the 'A' or 'B' position.
Specifi cations:
Input:
125V~/12A, 60Hz
Output voltage:
125V
Breaker:
15A
Outlets:
2 cycling, 880W, 10A each
2 auxiliary, 88W, 1A each
Power cord:
15' nominal, 14AWG, 3-wire
Timer:
15-240 minutes
Housing material:
20GA steel
Mounting type:
screw
Dimensions:
14.5"W [368.3mm] x 3.32"D
[84.3mm] x 4.01"H [101.9mm]
Regulatory listing:
ETL recognized component
Optional Cycle Timer
On / Off switch
(controls power to timer
& 'A' and 'B' outlets)
• Do not use the auxiliary outlets to charge multiple laptops or devices (use the 'A' and 'B' outlets only.)
Auxiliary outlets are for peripheral use only.
• Switch the timer power switch OFF before unplugging or plugging-in the main power unit plugs.
• Total equipment load not to exceed 12-amps per power unit.
• Do not plug the power cord into an extension cord.
• Inspect power cord before each use.
• Do not use power cord that is damaged.
• Do not unplug by pulling on the cord.
• Do not step on, drive over, drag, or place objects on the power cord.
• For indoor use only. Do not install or store the unit where it will be exposed to moisture. Keep dry.
• For added safety, plug the timer into a grounded three-prong receptacle controlled by a GFI
(Ground Fault Interrupter) circuit breaker.
timer
left (A) power
control
unit outlet &
indicator
Note: Each cart power unit
to be plugged into a separate
outlet ('A' or 'B').
CAUTION
Note: For PLUGGABLE EQUIPMENT, the
socket-outlet shall be installed near the
equipment and shall be easily accessible.
cycle switch
right (B) power
auxiliary
unit outlet &
(constant-power)
indicator
2-outlets used for
accessories such as
wi-fi routers, teacher
laptops, or printers
0106462R16 Page 14 of 19