Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 59
Function/Range Switch Instruction
Switch Position
Input Terminal Instruction
Positive input terminal for the sampled voltage for battery
internal resistance measurements.
It must be connected to the positive terminal of the vehicle's battery to be tested.
Input terminal for current measurements < 400mA. Positive input terminal for K
must be connected to the positive terminal of the vehicle's battery to be tested.
Negative input terminal for K type thermocouple for temperature measurements. Input terminal of the test current for battery
internal resistance measurements, it must be connected to the negative terminal of the vehicle battery to be tested. Common Creturn)
terminal for the other measurements.
sampled voltage for battery internal resistance measurements, it must be connected to the negative terminal of the vehicle battery to
be tested.
Measurement Function
AC voltage from 0V to 600V. DC voltage from 0V to 600V.
.
Diode test. Displays "0L" above 2V.
Continuity test. Buzzer turns on at < 30 and turns off at > 50 .
Frequency from 1Hz to 400kHz
AC or DC A from 0IA to 4000 A
AC or DC mA from 0mA to 400mA.
Duty cycle from 5% to 95%
Battery internal resistance from 0
Celsius degree from -20° C to 1000° C.
Fahrenheit temperature from -4°F to 1832°F.
Dwell angle
Turn off the meter
19