Technical Data Table - Lamborghini Caloreclima NINFA 24 MCS Instrucciones De Uso, Instalación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 92
NINFA 24 MCS

4.4 Technical data table

The column on the right gives the abbreviation used on the technical dataplate.
Data
Max. heating capacity
Min. heating capacity
Max. Heat Output in heating
Min. Heat Output in heating
Max. Heat Output in hot water production
Min. Heat Output in hot water production
Burner nozzles G20
Gas supply pressure G20
Max. pressure downstream of gas valve (G20)
Min. pressure downstream of gas valve (G20)
Max. gas delivery G20
Min. gas delivery G20
Burner nozzles G31
Gas supply pressure G31
Max. pressure downstream of gas valve (G31)
Min. pressure downstream of gas valve (G31)
Max. gas delivery G31
Min. gas delivery G31
Efficiency class Directive 92/42 EEC
NOx emission class
Max. working pressure in heating
Min. working pressure in heating
Max. heating temperature
Heating water content
Heating expansion tank capacity
Heating expansion tank pre-filling pressure
Max. working pressure in hot water production
Min. working pressure in hot water production
Hot water content
DHW flowrate Δt 25°C
DHW flowrate Δt 30°C
Protection rating
Power supply voltage
Electrical absorption
Electrical absorption in hot water production
Empty weight
Type of unit
PIN CE
GB
Unit
no. x Ø
no. x Ø
cod. 3540F611 - 05/2007 (Rev. 00)
Value
kW
25.8
kW
8.3
kW
24.0
kW
7.2
kW
24.0
kW
7.2
11 x 1.35
mbar
20
mbar
12.0
mbar
1.5
3
2.73
m
/h
3
0.88
m
/h
11 x 0.79
mbar
37
mbar
35.0
mbar
5.0
kg/h
2.00
kg/h
0.65
-
-
3 (<150 mg/kWh)
bar
3
bar
0.8
°C
90
litres
1.0
litres
8
bar
1
bar
9
bar
0.25
litres
0.2
l/min
13.7
l/min
11.4
IP
X5D
V/Hz
230V/50Hz
W
110
W
110
kg
33
C12-C22-C32-C42-C52-
C62-C72-C82-B22
0461BR0844
(Q)
(Q)
(P)
(P)
(NOx)
(PMS)
(tmax)
(PMW)
(D)
59