Gb.9.2.2 Micro Filter; Gb.9.2.3 Exhaust Filter; Gb.9.3 Changing The Power Cord; Gb.9.4 Spares And Accessories - Tennant 3400 Manual De Operador

Ocultar thumbs Ver también para 3400:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

GB
The new paper filter bag may now be installed. Simply locate
the cardboard edges of the paper bag mounting plate into the
locating grooves in the tank and slide the bag down into
position.
The suction hose coupling may now be reinserted into the tank
socket - insert the coupling and lock into position by rotating
clockwise.
GB.9.2.2
Micro filter
GB.10.
TROUBLE SHOOTING
PROBLEM
Machine does not operate
Poor vacuum performance
Poor brush pick-up.
(02-02)
CAUSE
Faulty power cord.
Faulty On/Off switch.
Loose wiring.
Building circuit breaker tripped.
Internal thermal overload sensor tripped.
Worn carbon brushes in vacuum motor.
Defective vacuum motor.
Full bag.
Clogged cartridge filter.
Loose vacuum hose connections.
Defective vacuum hose.
Tank lid not closed tightly.
Clogged hose.
Clogged tank coupling.
Entangled debris in brush.
Worn brushes.
Worn nozzle wheels.
Home
Find...
Go To..
Vacuum cleaner/ Aspirateur à poussière/ Aspiradora
The micro filter is secured in position above the motor by means of
a simple press fitting. Two recesses, in the motor hood, below the
cartridge filter, on the left and right sides, allow you to insert the
middle fingers of both the left and right hands and gently pull
upwards on the underside of the cartridge filter. To replace the new
or cleaned cartridge simply push it gently downwards onto the
mounting ring.
GB.9.2.3
Exhaust filter
The exhaust filter is designed to primarily filter the carbon dust from
the carbon brushes of the motor. It is situated on the front of the
machine, in the chassis, under the tank socket. Pull the filter
outwards by firmly holding onto the black plastic tab/handle. Open
the filter frame which now exposes the filter fleece. Replace the
fleece, close the frame and reinsert it into the machine.
The exhaust filter should be changed at least every six months.
GB.9.3
Changing the power cord
A damaged cord can be easily replaced. After disconnecting the
plug from the main power supply, turn the machine over to
expose the chassis. Slide the plug retaining clip forwards and
flip upwards to expose the plug. Remove the old plug with cord
and reinsert the new plug with cord. Flip the retaining clip down
and slide it back. A click will be heard once it is in position.
FOR SAFETY:
When servicing machine, unplug cord
from wall outlet. Use manufacturer supplied or approved
replacement parts.
GB.9.4
Spares and accessories
Should you require spares, accessories or consumables, please
contact your distributor.
SOLUTION
Change power cord.
Contact Service Center.
Contact Service Center.
Reset circuit breaker.
Disconnect the cord from the main supply for at
least 20 minutes. Remove air obstruction. Motor will
restart when the temperature has cooled down.
Contact Service Center
Contact Service Center
Replace bag.
Replace secondary filter.
Tighten hose connections.
Replace hose.
Close lid.
Remove clogged material.
Remove clogged material.
Remove clogged material.
Replace brush strips.
Replace wheels.
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

610782610783

Tabla de contenido