3.4 - Replacement of Power Cord:
Loosen the fastening device from the cord at the bottom of the compartment.
•
To remove the conductors, loosen the terminals and replace the cable. The new one must have at least the
•
characteristics on the Technical Data Table. The earth wire must be longer than the phase and neutral wires.
Make sure that the power cord is not subject to traction and that it is not twisted or knotted, which could cause heating.
•
The manufacturer will not accept responsibility either for defective operation or damage if the recommendations in this manual are
not followed.
4 - Recommendations for the User
This cooling unit has been designed for keg boxes and stock cabinets. To ensure that they function well, the following points must
be followed:
Do not block the frontal air vent as this will seriously affect the efficiency of the compressor.
•
Do not use pointed objects to remove ice - that could damage the evaporator and be dangerous to health and
•
environment.
If you do not follow the advises above, there will be an increase usage electrical energy.
•
4.1 - Start-up
Make sure that the plug is correctly inserted in the socket or that the appliance's circuit breaker is on.
After this, switch on the appliance. To do so, all you have to do is:
⇒ Press button "A", placing it in the "ON" position. The green light will come on and indicate connection. At the same time, the
display will flash for some seconds until it indicates the inner temperature.
⇒ Temperature is controlled automatically through the electronic thermostat "B".
4.2 - Defrost:
The appliance defrosts automatically. Switch "B" goes on according to the defrosting stage. After defrosting the switch goes off
automatically - it is also possible to do manual defrosting (besides the ones already programmed).
It is advisable not to open the doors after defrosting so that the normal temperature is obtained more rapidly. Defrosting and
condensation water goes into a tray placed under the evaporator and is directed to a collecting tray , where it is evaporated.
4.3 - Cleaning:
To ensure perfect hygiene and conservation, please clean as follows:
Cleaning the surfaces carefully with a damp cloth.
•
Always when using water and detergent, make sure these are neutral, and avoiding those which are chlorine-based
•
or abrasive.
Rinsing with clean water and drying carefully.
•
It is entirely inadvisable to use pressurised jets of water, specially in the direction of the compressor.
•
MNS00007.01
TEC 00
Instruction Manual
Power cord:
- Type
- Nominal Section
- Producer Code
- Great Britain
N.º
HO5VVF
3 x 1 mm2
43001001
43001003
MNS00007.01
9/9