6. Measuring methods
BEFORE PROCEEDING MEASUREMENT, READ
SAFETY NOTES ON PAGE 1.
WARNING
In proceeding with measurement, if "
appears on the display, replace with new batteries.
(1) Earth voltage check
a. Test leads connection
E
b. Turn the function switch to the "EARTH
VOLTAGE" position, then press the TEST
button to test.
P
Green
Yellow
Earth
Auxiliary
Electrode
Earth
under test
Spikes
Fig. 1
-8-
" symbol