6.14 LUBRICATION
All lubrication points according to the table below
must be lubricated after every 50 operating hours
as well as after each clean.
Use a grease gun, filled with universal grease.
Pump until grease protrudes. The lubrication
points are shown in fig. 19-20.
Note the belts when lubricating. Belts
must not come into contact with oil or
grease.
Object
Lubrication nipples /
action
Tension arm,
1 lubrication nipple.
pump belt
Lifting fork,
1 lubrication nipple
turning
Lifting fork, up-
2 lubrication nipples
down
Lifting cylinder 2 lubrication nipples
Control cylinder 2 lubrication nipples
Pivot point
3 lubrication nipples
Throttle cable
Lubricate the cable ends
using an oil can at the
same time as activating
the respective control.
Preferably carried out by
two people.
6.15 VALVES
Valve adjustment and grinding should be carried
out by authorised workshops.
92
ENGLISH
6.16 FUSES
The current strengths given in this sec-
tion are the maximum values of the fuse
that may be installed. If a higher cur-
rent fuse is installed there is a risk of
fire damage to the machine.
The machine has two fuse boxes.
Two fuse boxes (18:A and 18:B) are located in ac-
cordance with fig. 18. These contain the fuses ac-
cording to the table below. Depending on the
comfiguration of the machine some of the loca-
Fig.
tions may be empty.
In the event of electrical faults, check and replace
20:F
blown fuses. If the fault persists, contact an author-
ised workshop.
20:A
Fault
20:B
Dipped beam
AC
20:D
Main fuse, cabin
20:E
Turn signal lamps
20:C
Spare
19
Parking lights, Horn,
Dipped beam relay
Hazard
AC
Indicator lamps, buzzer,
hold valve transport posi-
tion
Cutting height, sand
spreader, rear rake
Cruise control, alternator
Electric socket on panel
Shut off pull
PTO, warning lamp park-
ing, safety relay
Spare
Main fuse
GGP reserves the right to make alterations to the
product without prior notification
Original instructions for use
Fuse
Location
Rating
18:A1
20 A
18:A2
20 A
18:A3
30 A
18:A4
10 A
18:A5
18:A6
10 A
18:A7
10 A
18:A8
10 A
18:B1
10 A
18:B2
20 A
18:B3
10 A
18:B4
10 A
18:B5
30 A
18:B6
10 A
18:B7
18:B8
40 A