Function 11 – Amperometric sensitivity in slow Open from 01 to 99
Ÿ Hold the P3 until the display shows
Ÿ Press repeatedly P2 until
Ÿ Press P3, the display shows
Ÿ Press the button P1 to increase and P2 to decrease the value
To disable the control, set
Note: id. 01= very sensitive – 99= less sensitive.
If you want to quit the programming mode follow the procedure for ESC:
Press P2 (Forward) or P1 (Backward) until you see
Confirm pressing P3.
Function 12 – Amperometric sensitivity in slow Close from 01 to 99
Ÿ Hold the P3 until the display shows
Ÿ Press repeatedly P2 until
Ÿ Press P3, the display shows
Ÿ Press the button P1 to increase and P2 to decrease the value
To disable the control, set
Note: id. 01= very sensitive – 99= less sensitive.
If you want to quit the programming mode follow the procedure for ESC:
Press P2 (Forward) or P1 (Backward) until you see
Function 13 – Starting blow from 1 to 20 (tenths of a second)
Ÿ Hold the P3 until the display shows
Ÿ Press repeatedly P2 until
Ÿ Press P3, the display shows
Ÿ Set the time in tenths of a second
Ÿ Press the button P1 to increase and P2 to decrease the value. Ex. (
Ÿ Press P3 for confirmation
If you want to quit the programming mode follow the procedure for ESC:
Press P2 (Forward) or P1 (Backward) until you see
Confirm pressing P3.
e release P3
appears on the display
.
equal to the sensitivity set.
.
e release P3
appears on the display
.
equal to the sensitivity set.
.
e release P3
appears on the display
.
= Disabled.
Confirm pressing P3.
.
)