REPLACING THE TOP BURNER NOZZLE (Ø 110 - 7 KW)
To carry out this operation, proceed as follows.
Turn off the gas supply
1)
tap.
Remove the grid (A).
2)
Extract the burner (B).
3)
Unscrew the nozzle (C)
4)
and replace it with the
one suitable for the type
of gas in use (see table at
back of manual).
Replace the burner and
5)
the grid.
REPLACING THE TOP BURNER NOZZLE (Ø 130 - 10 KW)
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Pull off the knob (A).
2)
Undo the screws (C) and remove the control
3)
panel (B).
Unscrew the nozzle (D) and replace it with
4)
the one suitable for the type of gas in use (see
table at back of manual).
Replace the control panel (B) and the knobs
5)
(A) on completion of the operation.

REPLACING THE TOP BURNER PILOT LIGHT NOZZLE

To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Pull off the knob (A).
2)
Undo the screws (C) and remove the control
3)
panel (B).
Unscrew the union (D).
4)
Remove the nozzle (E) and replace it with the
5)
one suitable for the type of gas in use (see
table at back of manual).
Retighten the union (D).
6)
Replace the control panel (B) and the knobs
7)
(A) on completion of the operation.
3319960_inst_GB_rev.1
A
B
- 13 -
C
A
C
B
C
A
C
B
8
C
D
8
D
E
10
ENGLISH