Listed/Certified to latest
published edition of
ANSI
or its successor standard,
Cover/Grate or Suction
Fitting, Securely-fastened
to Main Drain Sump
Suction Outlet
(Main Drain)
WARNING: Suction check valves and hydrostatic valves should not be used with this pump.
Figure 1.
Number of Suction Outlets Per Pump
Section 2.
Installation of the
Digital Controller
2.1
Introduction
This document provides general instructions to
install and operate the JEP-R Variable-Speed Digital
Controller. The controller can be mounted to an
electrical gang box (single, double, or triple) or to a fl at
wall.
The instructions have been written with safety as the
priority, and must be followed exactly. Read through the
instructions completely before starting the procedure.
2.2
The Controller Panel
The controller panel provides both timed and manual
speed controls for the Variable Speed Pumps.
Four (4) speeds are directly available on the panel,
while four (4) additional speeds may be accessed via the
key.
MENU
LCD Display
LED Lights
PRESS SPEED OR MENU
12:00AM
2
eStar Button
Menu Button
Figure 2.
JEP-R Controller Panel
JEP-R Variable-Speed Pump Controller
/ASME
A112.19.8
®
®
ANSI/APSP-16
Anti-entrapment
Valves OK between
Pump and Tee
Up/Down
Arrow Keys
PUMP IS OFF
3
4
Preset Speed
MENU
Buttons
|
Installation Manual
At Least
3 Feet
No Valves between
Tee and Main Drains
The up and down keys are used to adjust the pump
speed. The speed is saved as it is adjusted. No further
action is required to save the new speed setting after
adjustment. The selected speed can be saved and
assigned to one of the speed buttons.
As shown in Figure 2, preset speed "
the "eStar" feature. Hence, it is intended to be assigned
an energy-effi cient fi ltration speed, as determined by the
installer.
4
Figure 3.
Controller Components
2.3
The Controller Components
The controller assembly contains the following
components. See "Figure 3. Controller Components":
1. Controller
2. Mounting Gasket
3. Backplate
4. Six (6) Screws
ENGLISH
Listed/Certified to latest
published edition of
ANSI
/ASME
A112.19.8
®
®
or its successor standard,
ANSI/APSP-16
Anti-entrapment
Cover/Grate or Suction
Fitting, Securely-fastened
to Main Drain Sump
Suction Outlet
(Main Drain)
Pump
External Brackets
For Wall Mounting
2
1
PAGE 7
" is assigned to
3