Tradesman Construction Heaters
TRADESMAN 400 DUAL FUEL
When using propane as the fuel:
1. Assemble the components as shown in Fig. 7.
2. Tighten all components securely
FIG. 7
BUSHING, 3/4 IN.
When using natural gas as the fuel
Do not use the POL fi tting.
1. Ensure the natural gas supply has line pressure of minimum
2 PSIG up to a maximum of 20 PSIG.
2. Connect the hose to the regulator's outlet and at the heater's
gas inlet.
3. Connect the regulator to the natural gas supply using the
appropriate fi ttings.
4. Tighten all connections securely.
Connecting Propane Regu-
lator to Propane Gas Supply
1. At the inlet of the regulator is a male nut and stem
called a POL. Remove the cap from the POL but do not
discard it. Insert POL stem into the valve on the propane
fuel container. Thread the nut counterclockwise into the
container's valve. Tighten the nut securely with a wrench.
See Fig. 7.
2. Slowly open the tank or cylinder valve. This will prevent
lock-up of the excess fl ow valve within POL stem.
3. Check all connections with approved leak detector. Do not
use fl ame to check for leaks. A fi re or explosion may result.
4. When storing or transporting the heater, ensure the cap is
pushed back onto the POL fi tting to protect the fi tting from
damage and prevent entry of dirt.
Owner's Manual • Tradesman
HOSE ADAPTER
BUSHING, 1 IN.
POL FITTING
FIG. 8
POL NUT
AND STEM
Height Adjustment
Tradesman 170
Tradesman 170 heaters include a height adjustment
feature, allowing the user to change the elevation of the
heater for greater heat direction. See Fig. 9 for location of
adjustment on front base of heater.
To adjust the heater's discharge outlet height:
-- Loosen knob
-- Lift heater slightly at blower outlet end
-- Pull leg to desired setting
-- Tighten knob.
WARNING
Burn Hazard
■ Do not adjust height while heater is operating
or hot.
■ Adjust height only after the heater has been
disconnected from its power supply and cool
to touch.
■ Failure to follow this warning will result in burns
causing injury.
FIG. 9