ELECTRICAL REQUIREMENTS AND SAFETY
Use a separate electrical circuit for your tool. This circuit must
not be less than #12 wire with a 20 A time-lag fuse or a #14
wire with a 15 A time-lag fuse.
NOTE: When using an extension cord on a circuit with a #14
wire, the extension cord must not exceed 25 feet in length.
Before connecting the motor to the power line, make sure the
switch is in the off position and the electric current is rated
the same as the current stamped on the motor nameplate.
Running at a lower voltage will damage the motor. This tool is
intended for use on a circuit that has a receptacle like the one
illustrated in Fig. A.
Fig. A shows a three-pronged electrical plug and receptacle
that has a grounding conductor. If a properly grounded recep-
tacle is not available, an adapter (sold separately)
(Fig. B) can be used to temporarily connect this plug to a
twocontact grounded receptacle. The adapter (Fig. B) has a
rigid lug extending from it that MUST be connected to a per-
manent earth ground, such as a properly grounded receptacle
box.
WARNING
Never remove the grounding prong from
the power cord. If damaged, discontinue use of unit
and contact customer service for a replacement cord.
Fig. A
PREPARATION
Before beginning assembly or operation of the product, make
sure all parts are present.
Compare parts with package contents list and diagram above.
If any part is missing or damaged, do not attempt to assem-
ble, install or operate the product. Contact customer service
for replacement parts.
• Estimated Assembly Time: 40-60 minutes
• Tools Required for Assembly and Adjustment:
RECOMMENDED
ACCESSORIES
Use only the recommended
accessories with this table
saw. Follow the instructions
that are supplied with these
accessories.
308K DADO INSERT PLATE
CAUTI ON
• Do
not use adjustable or
wobble-type dado's.
Use stackable dado
sets only. Maximum
dado width is 1/2 in.
Three-Pronged Plug
Grounding Prong
Properly Grounded
Three-Pronged Receptacle
Supplied
Blade Wrench
Blade Wrench
4 mm Hex Wrench
Fig. B
Grounding Lug
WARNING
• In all cases, make certain the
receptacle is properly grounded. If you are not sure,
have a qualified electrician check the receptacle.
• This tool is for indoor use only. Do not expose to rain or
use in damp locations.
• This tool must be grounded while in use to protect the
operator from electric shock.
MINIMUM GAUGE FOR EXTENSION CORDS (AWG)
(When using 120 volts only)
Ampere Rating
More than
Not more than
0
6
6
10
10
12
12
16
• Do not use a dado with a diameter greater than 6 in.
• Do not attempt to use a dado set without the proper dado
insert plate secured in place.
• Do not use a molding head set with this saw.
• Do not modify this saw or use accessories not
recommended by customer service.
Adjustable Wrench
and/or 13 mm Wrench
5, 6 mm Hex Wrench
Combination Square
5
Make sure this
is connected
to a known
ground.
Two-Pronged
Receptacle
Adapter
Total length of Cord
25ft. 50ft.
100ft.
18
16
16
18
16
14
16
16
14
14
12
Not Recommended
Phillips Screwdriver
NOT Supplied
Slotted Screwdriver
150ft.
14
12