Ø
1
2
3
2
English
Lift the cartridge out (1).
Turn the cartridge 180°, so that the "hot side"
marking is on the right (2).
Install the cartridge (3)
Install the nut (4).
Continue the installation.
4
Adjust the Rotational Limit Stop
Adjust the rotational limit stop if:
The maximum output temperature is greater
than 120°F or that permitted by local plumb-
ing code
The temperature of the incoming hot or
cold water supply changes seasonally, or if
changes are made to the water heater.
Turn the rotational limit stop, clockwise to make
the water cooler, counter-clockwise to make it
warmer.
Depending on local conditions, each notch repre-
sents a change in temperature of 4°F - 16°F.