25.5 Conexión de relevador reversible para Estación Remota
+
-
Up to 60 hours of battery standby time can be supplied
using three or four 7.0Ah, sealed, Lead-Acid batteries.
Four 7.0Ah batteries may be required based on total current
draw of all devices connected to the panel. See section
titled 24 VDC NAC Standby Battery Calculations.
To connect four batteries to the XR200 Command
Processor™ Panel, use three Model 318 Battery Harnesses.
+
-
XR200 Guía de Instalación
DIAGRAMAS DEL SISTEMA
J12
J11
J3
J4
DD, MPX
Tamper
Selection
Header
Headers
Answering Machine
Ground Start Relay
Bypass Relay
K2 K4
Use Model 305
Use Model 305
J10
Relay Output 1
Use Model 305
AC
AC
+B
-B
BELL GND
RED YEL GRN BLK
1
2
3
4
5
6
7
8
9
10
S
S
S
S
S
S = Supervised Circuit
+
+
All modules must be installed in a
UL Listed enclosure connected by
no more than 20 feet of conduit.
XR200 Command Processor™ Panel
Note: Output 3 must be programmed as a Fire Alarm
Output and Output 4 must be programmed as a Fire
Trouble Output. See Output Options section of the
XR200/XR2400F Programming Guide (LT-0196).
J2 Output Header
All outputs must be located
within the same room as
the control panel.
J2 Output Header
Relay Output 2
K6 K7
Use Model 305
SMK GND
Z1
GND
Z2
Z3
GND
Z4
Z5
GND
11
12
13
14
15
16
17
18
19
20
Reversing Relay Module
Radionics Model D127
5mA Standby, 55mA Alarm
-
@12 VDC
Alternate Alarm
Combo Alarm
Auxiliary Power In
+ Signal Voltage In
+ To Remote Receiver
- To Remote Receiver
- Signal Voltage In
EARTH GROUND
GROUND
GROUND
Intended for connection to a
polarity reversal circuit of a
remote station receiving unit
having compatible ratings.
-
Alternate Alarm
Combo Alarm
Auxiliary Power In
+ Signal Voltage In
+ To Remote Receiver
- To Remote Receiver
- Signal Voltage In
EARTH GROUND
GROUND
GROUND
Reversing Relay Module
Radionics Model D127
5mA Standby, 55mA Alarm
@12 VDC
Model 430
Output Harness
Outputs 3 through 6 supply
up to 50mA at 12 VDC.
J16
Panel
Reset
Z6
Z7
GND
Z8 Z9+ Z9- Z10+ Z10-
21
22
23
24
25
26
27
28
Fire Alarm Output 3 -
White/Orange
To Telephone Line
Fire Trouble Output 4 -
White/Yellow
To Telephone Line
Digital Monitoring Products
29