D12
D13
D30
D72
D73
D74
D75
2.7.
Option Boards
2.7.1.
Wiring Connections for Options
Options available for the IND780 terminal include the following:
64057253
|
14
|
08/2014
LED
Color
Yellow
Indicates 12V supply is present.
Yellow
Indicates 5V supply is present.
When lit, indicates USB port has been identified and is functional.
Green
Note that this LED remains lit whether or not a USB device is connected.
Amber
Used for software development purposes; blinking during normal system operation.
Yellow
Indicates that an Ethernet connection exists.
When blinking, indicates that the Ethernet connection is actively receiving or
Green
transmitting data.
When lit, indicates that Ethernet connection is 100 MB.
Red
D73 lit, D75 off, indicates that Ethernet connection is 10 MB.
•
Analog Load Cell
•
®
POWERCELL
MTX
®
•
POWERCELL
PDX
•
Flow Meter Interface
•
Discrete I/O (Relay) and Solid State Relay
•
SICS High Precision Balance Interface
•
IDNet Scale Interface
•
Serial Communications
Table 2-5: Main PCB LEDs
Function
•
Analog output
®
•
Rockwell (Allen-Bradley) RIO
®
•
ControlNET
•
DeviceNet
•
Ethernet/IP and Modbus TCP
•
Profibus (Harsh Enclosure)
•
Profibus (Panel Enclosure)
•
Profinet
METTLER TOLEDO IND780 Installation Guide