DETERMINE INSTALLATION HEIGHT
• Decorative duct covers are provided to conceal
the ductwork running to the ceiling.
• This hood can be installed for recirculating
operation. Recirculating Kit included with hood.
24" Min.*
30" Max.*
36" Min.
NOTE: Installation height should be measured from
the cooking surface to the flat portion of the bottom
of the hood.
For optimum performance, the hood must be
24" min. and 30" max. above the cooking surface.
The hood installation height depends upon ceiling
height.
Installation Preparation
* Exact installation
height depends
on ceiling height.
12
PV977 – Island
Upper Duct Cover
Lower Duct Cover
Actual
Ceiling
*Possible VENTED
Height
Installation Height
7' 11"
24"
8' 0"
24" to 25"
8' 1"
24" to 26"
8' 2"
24" to 27"
8' 3"
24" to 28"
8' 4"
24" to 29"
8' 5"
24" to 30"
8' 6"
24" to 30"
8' 7"
24" to 30"
8' 8"
24" to 30"
8' 9"
24" to 30"
8' 10"
24" to 30"
8' 11"
24" to 30"
9' 0"
24" to 30"
9' 1"
24" to 30"
9' 2"
24" to 30"
9' 3"
24" to 30"
9' 4"
24" to 30"
9' 5"
26" to 30"
9' 6"
26" to 30"
9' 7"
27" to 30"
9' 8"
28" to 30"
9' 9"
29" to 30"
9' 10"
30"
9' 11"
10' 0"
10' 1"
10' 2"
10' 3"
*Based on 36" countertop height
29.92
25.98
Counter to Hood Height
*Possible
RECIRCULATING
Installation Height
24"
24" to 25"
24" to 26"
24" to 27"
24" to 28"
24" to 29"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
24" to 30"
25" to 30"
26" to 30"
27" to 30"
28" to 30"
29" to 30"
30"