If the power cord is damaged, it must be replaced by the manufacturer, by its after-
sales service or by similar qualified personnel in order to avoid a danger.
The power supply cable must be connected to the connection provided according to
current regulations.
Disconnecting means must be incorporated into the fixed installation in accordance
with the installation regulations.
IMPORTANT!
The machine must be connected to a properly earthed connection.
Check that the electricity system can support the machine's power requirements
before turning it on. It is possible to limit the maximum power of the machine
using the configuration software, limiting the number of heating elements that
work at the same time (see Section 12).
The power and amperage table, based on the configuration of the number of heating
elements working at the same time, is given below:
BABY T 230V
BABY T 110V
The standard configuration of this CE parameter is CE=2 for all models.
MANUAL BABY T ENG-ESP_DE 2020 .indd 11
MANUAL BABY T ENG-ESP_DE 2020 .indd 11
Machine code Machine number
Model
Cycles
Voltage
Boiler pressure
Boiler capacity
Coffee (W)
Steam (W)
1 x 1000
1 x 1200
1 x 1000
2 x 600
Power
Current rate
Manufacture date
Total A
CE Parameter
1
10
5,5 A
20
9 A
2
3
10A
10A
12 A
20 A
22/09/2020 16:29:10
22/09/2020 16:29:10
11