IN THE EVENT OF PROBLEMS
Problem
No steam
exiting
Appliance
leaking
Delay in steam
output
Red indicator
[A] illuminated
If the problem persists, please contact customer service.
8
T
ECHNICAL DETAILS
Rated output
Nominal voltage
Water tank volume
Evaporation rate
Overheating protection
Safeguard against running dry
Switching
Weight
Dimensions (W / H / D)
Connection
Cause
Appliance not connected to power
Water tank [8] empty.
Water tank [8] not fitted correctly.
Water tank [8] leaking.
Water tank [8] not shut properly.
Steam tower [3] not installed or not
installed correctly.
Very cold water in tank.
Appliance heavily scaled.
Water tank [8] empty.
Valve on tank catch [9] is covered
with dirt.
Appliance heavily scaled.
Water tank [8] not shut properly.
Water tank [8] not fitted correctly.
380 W
230 V / 50 Hz
approx. 5 litres
Level 1: 150 ml/h
Level II: 400 ml/h
Through thermostat
If there is not enough water in the heater unit, the
appliance switches off automatically. The appliance has
a sensor which detects the water level.
2-stage
2.8 kg
235 / 315 / 280 mm
Fixed cable, approx. 2 m in length
Remedy
Insert the plug [14] into the
mains and
appliance.
Replenish water.
Fit tank properly.
Replace tank.
Fasten the catch properly.
Install steam tower [3]
properly.
Use warmer water.
Descale the appliance.
Replenish water.
Clean the valve.
Descale the appliance.
Close the catch properly.
Fit tank properly.
19
switch on the