Installation and electrical connection
▶ Pump is installed.
6.3

Electrical connection

DANGER
Risk of death due to electrocution!
Improper conduct when carrying out electrical work can lead to death due to elec-
tric shock! Electrical work must be carried out by a qualified electrician in accord-
ance with the locally applicable regulations.
▪ Power grid with correctly installed protective earth conductor.
▪ RCD (residual-current device) with 30 mA is installed.
▪ Max. fuse protection 16 A.
▪ The technical data of the product (see rating plate) must match the data of the power
grid.
▪ Connection cable with plug:
– Equip socket with earth contact.
▪ Connection cable without plug:
– Electrical connection must be carried out by a qualified electrician!
– Earth the device properly!
– Provide a motor protection switch!
Do not connect the pump if:
▪ The connection cable is damaged
Have the connection cable replaced by a qualified electrician or customer service.
▪ A standalone inverter is in use
Standalone inverters are used in autonomous power supply (such as solar power) and
may cause overvoltages. Overvoltages can destroy the pump.
▪ A multiple plug socket or power strip is in use
▪ An energy-saving plug is in use
These reduce the energy supply to the pump which may cause the pump to become
too hot.
Installation and operating instructions Wilo-Rexa MINI3
7. Route the connection cable to the socket/power supply. WARNING! Route the
connection cable so that it poses no danger (e.g. tripping hazard)!
Qualified electricians are people with the technical and professional training to
correctly connect the product to the local power grid. Furthermore, qualified elec-
tricians are able to recognise and avoid the dangers caused by electricity thanks to
their knowledge and experience.
The minimum requirement is a thermal relay/motor protection switch with temper-
ature compensation, differential protection relay and an anti-reactivation device in
accordance with the local regulations.
en