ESSENTIAL CIRCUIT
ISOLATION
Essential electrical loads are loads that will be powered by
the Standby Generator System. Essential loads are grouped
together and wired into the transfer switch.
TO THE INSTALLER: Consult with Standby
Generator System owner(s) to discuss their
"Selection of Essential Circuits", described in
owner's manual.
Figure 2 — Typical System Diagram with Essential Circuits
240V
Generator Supply
To Briggs & Stratton
Standby Generator
120V To Microwave
120 V To Bathroom
240V To Well Pump
120V To Sump Pump
Briggs & Stratton Power Products Manual Transfer Switch
Installation and Owner's Manual
To Range
To Water Heater
Utility Supply
www.mymowerparts.com
Ensure that the total of the selected load circuits fed by this
transfer switch are within the generator's rated capacity.
The following requirements apply to this type of isolation
system:
• The Manual Transfer Switch is installed after the main
distribution panel.
• The Manual Transfer Switch has a load rating of 60 Amps.
This is the maximum load rating of the essential loads.
All wiring must conform to national, state and local codes.
The illustration in Figure 2 depicts the Standby Generator
System and assumes the utility is supplying 120/240 Volt,
single-phase electrical service.
To Utility Power
To Air Conditioner (240V)
To Other Circuits (120V)
120V To Freezer
To Refrigerator
To Lights
To Furnace Blower
Neutral
6
Watt Meter
Main Distribution Panel
Manual Transfer Switch
(in utility position)
120V