There are 8 standard operating modes that can be selected for different applications (CO-01 function).
Default settings can be reset in programming mode.
Operation faults are stored in the memory (functions SO-00 > SO-59)
N.B. If power is shut off during programming without pressing RUN, the door will not operate and remains in STOP status even if power is restored
immediately.
Options already confirmed by pressing DATA/ENTER do not have to be reset and on re-entry, programming can be resumed.
Function
Name
CO-00
Speed constant (DO NOT TOUCH)
CO-01
Operating mode
CO-02
Opening width 1 (maximum)
CO-03
Impact sensitivity (DO NOT TOUCH)
CO-04
Opening speed
CO-05
Closing speed
CO-06
Low opening speed
CO-07
Low closing speed
CO-08
Speed gauge
CO-09
Automatic closing wait time
CO-10
Door Closing pressure
CO-11
Power lock activation during closing
CO-12
Siren activation
CO-13
Acceleration time on opening (starting torque) 100
PROGRAMMER SPECIFICATIONS
SELECTION OF FUNCTIONS AND OPTIONS
Lower limit
-
0
300
0
100
100
15
15
15
300
0
0
0
A - RUN: start pushbutton
B - FWD/REV – Day/Night function– when pressed the REV (F)
led illuminates and the electric lock (if fitted) is released.
C - JOG – total opening control - when pressed the FWD (E)
led illuminates and the door opens. Pressed again, the
FWD (E) led switches off and the door closes after the set
wait time.
D - PRGRM/DRIVE – control for opening to point set on CO-
02. When pressed the SEQ (G) led illuminates - pressed
again the SEQ led switches off and the door closes after the
set wait time.
E - FWD – opening movement indicator
F - REV – Day/Night function "on" indicator
G - SEQ – Indicator for opening to point set on CO-02
H - DSPL – enabled during STOP – used to set the operating
mode (CO "Operating function" or SO "event memory")
I - DATA/ENTER – Button for access to parameter
configurations – enabled during STOP.
L - UP/DOWN – pushbutton to increase/decrease numerical
values during programming
M - >/RESET – pushbutton used to confirm/select data on
display
N - STOP pushbutton – when pressed the led illuminates and
programming functions are enabled.
Upper limit
U. M
-
7
30000
mm
150
914
mm/s
914
mm/s
300
mm/s
300
mm/s
300
mm/s
60000
ms
10
1
1
2000
ms
Default settings
13180
0
00000
80
500
250
100
40
60
1800
04
0
1
800