sk tecnica irisplus multilingua_ristampa052009.qxp
TECHNICAL AND HEATING SPECIFICATIONS
Hopper capacity
Efficiency
Available power
Time between refuellings (min/max)
Fuel consumption
Test EN14785 smoke outlet temperature
Mass flow
CO Emissions (13% O2)
Heatable room dimensions (min/max)*
Weight including packaging
Smoke duct diameter (A male)
Air intake duct diameter (B male)
* The heatable room dimensions are calculated on the basis of pellets with a lhv
of at least 4300 kcal/kg and home insulation in compliance with Italian law 10/91.
It is also important to consider the location of the stove in the room to be heated.
N.B.
1) Bear in mind that external devices may cause interference.
2) Caution: live parts. Servicing and/or inspections must be carried out by qualified staff.
ELECTRICAL SPECIFICATIONS
Power supply
0/1 switch
Average power consumption
Power consumption during
ignition
Remote control frequency
(optional)
Protection on mains power
supply
Electronic circuit board
protection
SAFETY DEVICES
THERMOCOUPLE: on the smoke outlet.
It measures the smoke temperature.
It controls the ignition, operating and shutdown
stages according to the parameters set.
AIR FLOW SENSOR: on the intake duct. It trips
when the flow of combustion air is not correct,
therefore causing low pressure problems in the
smoke circuit.
SAFETY THERMOSTAT:
It trips if the temperature inside the stove is too
high. It stops pellet loading, thus causing the stove
to go out.
14/05/2009
11.38
15
89,2
3,4 / 8,3
7,5 / 17
0,7 / 2,0
174,9
5,5
71
115 / 230
157
80
40
230V
10% 50 Hz
ac +/-
yes
150
W
400
W
infrared
2A, 250 V
5x20
ac
Fuse
2A, 250 V
5x20
ac
FLOW
Fuse
SENSOR
The Dealer can install an optional on the AUX outlet
(clean contact, with no potential) for controlling the
process of switching on and off (e.g. telephone remote,
local thermostat), located at the rear oh the stove.
Can be connected via special optional trestle (code 621240).
16
Pagina 17
kg
%
kW
hours
kg/h
°C
g/s
ppm
m
3
kg
mm
mm
106 mm
SMOKE SPEED
THERMOCOUPLE
ROOM
SENSOR
SCREW FEEDER
MOTOR
SMOKE EXTRACTION
VENTILATION
MOTOR
HEATING ELEMENT
SAFETY
THERMOSTAT
215 mm
77 mm
600 mm
* with screwed in feet
P/TEMP.
VENTILATION
ADJUSTMENT
ADJUSTMENT
230 V AC MAINS
50 Hz +/- 10%
IGNITION
2A FUSE