BML SL1-ALZ _-_ _ ZZ- _ _ _ _ - _ _ _ _
Absolute Magnetically Coded Position Measuring System
Construction and function (continued)
Linear application
–Roll
+Roll
5
5
Linear application
Z
(gap between sensor/magnetic tape)
Z
(gap between sensor/magnetic tape
with cover strip)
Y (side offset)
Pitch
Yaw
Roll
Max. non-linearity of entire system
(sensor head + magnetic tape)
Non-linearity of sensor head
Hysteresis
Repeat accuracy
1) The different mounting tolerances must be met depending on the required measuring accuracy.
Curved application
Curved application
Z (gap between sensor/magnetic
tape)
Z (gap between sensor/magnetic
tape with cover strip)
Y (side offset)
X (tangential offset)
Pitch
Yaw
Roll
www.balluff.com
Aktive Messfläche
Freibereich magnetisierbarer
Materialien
Verfahrrichtung
Vorwärts, A (Sin) vor B (Cos).
Working range 1
≤ 0,4 mm
≤ 0,25 mm
±0,5 mm
±15 µm
±5 µm
≤ 1 µm
≤ 1 µm
Z
X
2000 mm
≤ 1,0 mm
0,85 mm
27.3
Z
1)
Working range 2
1)
≤ 1,0 mm
≤ 0,85 mm
±1,0 mm
±0,5°
±0,2°
±0,5°
±40 µm
±30 µm
≤ 2 µm
≤ 2 µm
–Pitch
+Pitch
Z
Diameter
1000 mm
≤ 0,6 mm
0,45 mm
±0,5 mm
32,5 mm ±1 mm
±0,5°
±1°
±0,5°
Y
+Yaw
–Yaw
–Pitch
+Pitch
Function range
1)
≤ 1,3 mm
≤ 1,15 mm
±1,5 mm
±100 µm
±40 µm
≤ 2 µm
≤ 2 µm
Tangential point
400 mm
≤ 0,1 mm
–
english
2