Ocultar thumbs Ver también para CMS-E Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions
Read Heads/Actuators with Hall Sensors for Evaluation Units CMS

Technical data

Parameter
Value
Read heads
Housing material
Fiber glass reinforced PPS
Ambient temperature
-5 ... +55 °C
Degree of protection
IP67
Degree of contamination
2
(external, acc. to EN 60947-1)
Installation position
Any, alignment with actuator
should be kept in mind (markings)
Connection
Molded cable with cable end
sleeves
Switching voltage
20 ... 35 V
Current consumption I
35 mA
max
Switching current I
15 mA
e max.
Method of operation
Hall sensor
Mechanical life
100 x 10
6
Center offset m from actuator ± 2.5 mm at distance s = 3 mm
Switch-on distance s
ao
Switch-off distance s
See combination options table
ar
Switching contacts
Actuator
Housing material
Fiber glass reinforced PPS
Degree of protection
IP67
Installation position
Any, alignment with read head
should be kept in mind (markings)
Center offset m from read
± 2.5 mm at distance s = 3 mm
head
Switch-on distance s
ao
Combination options
Switch-off distance s
ar
Design CMS-.-A...
Y
X
Approach
direction
Z
Design CMS-.-B...
Alignment marking
Y
X
Approach
direction
Z
Figure 1: Alignment of read head and actuator
CMS-RH-A..
CMS-MH-A.
operating cycles
CMS-RH-B..
CMS-MH-B.
See table
Alignment marking
The dimensions of the actuators are the
same as those of the read heads, although
the former have no connection cable or LED.
Figure 2: Dimension drawings for read heads CMS-RH-A.. / CMS-RH-B..
Dimension drawings for actuators CMS-MH-A. / CMS-MH-B.
Combination options for evaluation units CMS-E-ER and CMS-E-FR
1) There must be no ferromagnetic material in the vicinity of the read head or the actuator.
With a frontal approach direction, all data refer to a center offset of m = 0.
2) The assured switch-off distance s
3) Not connected (NC)
87,5
67,5
Center offset m at s = 3 mm
Actuator
2,5
Active face
∅ 5,5
78
±0,1
LED indicator
6 x 0,25 mm²
55
Circuit diagram
Design
Read head
not actuated
CMS-RH-AYA-...L
CMS-RH-BYB-...L
corresponds to the reset distance.
ar
4
2,5
6 x 0,25 mm²
8,5
4,5
Center offset m at s = 3 mm
Actuator
2,5
2,5
Active face
7
22
LED indicator
36
Assured
Actuator
switch-on
1, 3))
distance s
BN +
PK
WH
CMS-MH-AA
GY NC
BK
BU -
BN +
PK
WH
CMS-MH-BB
GY NC
BK
BU -
55
Assured
switch-off
[mm]
distance s
[mm]
2)
ao
ar
10
20
6
13

Publicidad