sv
•
(suction lock)= activating this function, at the start of the opening manoeuvre,
GB
a 12V suction lock is controlled after an activation time regulated by the parame-
tser
ter
sv=0
function not enabled (the exit is activated only for the
sv=1
function enabled (the exit remains active and deactivates only for the
time).
ar
•
(ramming on opening)= before starting the opening manoeuvre, motor 1 pu-
shes the door in closing for two seconds, allowing the electric lock to move away
from the fastener. At this point, the lock is activated and the manoeuvre continues
its normal opening movement.
ar=0
function not enabled.
ar=1
function enabled.
re
•
(energy saving)= keeps the photocells off while the system is not active, per-
mitting energy saving. The photocells therefore remain active only while the leaves
are in movement and during
re=0
function not enabled.
re=1
function enabled.
Connect the current feed +/-24V of both the transmitter and receiver of the pho-
tocells at fl asher exit.
1m
•
(one motor)= operation of the system only with motor 1.
1m=0
function not enabled.
1m=1
function enabled.
en
•
(encoder operation)= allows the system to operate also if there is an encoder
malfunction (the gate blocks shortly after the start of movement and the display
ENC1
shows
en=0
encoder not enabled.
en=1
encoder enabled.
WARNING: the operation of the system without encoder is to be considered as
being an emergency operation. In this mode every obstacle encountered by the
motors will make it stop. When the encoder is active instead, operating with
each obstacle encountered by the motors commands an reversal of movement by
approximately 30cm.
ss
•
(soft start)= allows the motor to undertake a soft start and at reduced speed
to diminish stress of the mechanical parts of the system. Activating this function,
the motors deliver less power in the starting phase.
ss=0
function not enabled.
ss=1
function enabled.
oc
•
(open/close function)= lthe START terminal input becomes OPEN and the
PEDESTRIAN terminal input becomes CLOSE. In this mode, one control opens
the gate and another closes it without intermediate stops. The PEDESTRIAN and
START functions can be activated with the radio control on the fi rst and second
channels respectively.
oc=0
function not enabled.
oc=1
function enabled.
27
.
ENC2
or
).
ttca
.
tser
time).
tser
it=0
,