Installation Instructions; Important Warnings - EdilKamin CRISTAL 45 Instalación Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32

INsTALLATION INsTRUcTIONs

Important warnings

As well as that indicated in the present
document, bear in mind the UNI rules:
- n. 10683/2005 - wood heat generators:
installation requirements
- n. 9615/90 - calculation of the chimney
internal dimensions.
In particular:
- before starting any mounting operation,
it is important to verify the compatibility of the
plant as established by the UNI 10683/2005
rule in paragraphs 4.1/ 4.1.1 / 4.1.2.
- once mounted, once mounted, the
installer must "start up" the plant and
issue the documentation requested in the
UNI 10683/2005 rule, respectively in
paragraphs 4.6 and 5.
Before installing the cover, verify
the correct functioning of the
connections, the controls and all
moving parts.
The verification must be carried
out with the chimney having been
on for a few hours, before covering the
hearth, in order to eventually intervene.
Therefore, the finishing operations such
as for example:
- manufacture of the false hood
- mounting of covering
- carrying out stripping, painting, etc.
must be carried out once tested with
positive result.
Therefore, Edilkamin does not answer for
burdens deriving from both demolition
and reconstruction interventions, even if
subsequent to replacing hearth pieces
which resulted faulty.
Calibration and start up to be carried
out by the dealer.
16
Vorwort
• The CRISTAL hearths must be installed keeping
to the following instructions, as the safety and plant
efficiency depend on the correct installation.
• Carefully read the present instructions before
mounting.
• EDILKAMIN declines any responsibility for
eventual damages deriving from the non
compliance with the present instructions and, in
case, any warranty right will be void.
• The CRISTAL hearth is supplied already
assembled on non returnable pallet.
The inside covering of the hearth is supplied
already installed
• A model identification label is applied under
the hearth hatch; the label can be seen until the
hearth is covered.
The model identification number is indicated in
the documentation supplied with the product.
Building protection
All the building surfaces near the hearth must be
protected against over-heating. The insulating
measures to be adopted depend on the type of
surfaces present and how they are made.
hot air outlets / Grillsr
The hot air outlets must be placed at a minimum
distance of 50 cm from the ceiling and 30 cm
from the furniture.
Position the grills or the air outlets at the highest
point of the covering, in order to avoid heat
accumulating inside the same covering. Position
the grills or the air outlets so that they can be
easily accessed for cleaning.
heating insulation
The insulating layers must not have joints and
have to be overlapped. The thickness of the
insulating material must be of at least 3 cm.
Ornamental beams
The realisation of eventual wood ornamental
beams in front of the hearth covering is allowed
only if they are outside the radiation field, at a
distance of at least 1 cm from the same covering.
The air space which isolates the ornamental
elements and the covering must be such not to
accumulate heat.
The wood ornamental beams cannot be
integrating parts of the building.
Floor opposite the hearth
Floors made with fuelling materials must be
protected by a sufficiently thick, non fuelling
cover.
The floor protection must be equal to:
frontally:
- the corresponding height of the fire surface
from the floor plus 30 cm and, in any case, min.
50 cm
laterally:
- the corresponding height of the fire surface
from the floor plus 20 cm and, in any case, min.
30 cm.
In the radiation field of the hearth
The structural elements built with fuelling material
or which present fuelling components and the
furniture must be positioned at a minimum
distance of 80 cm from the hearths mouth, in all
three directions: front, upper and side.
Should such elements or furniture be screened
by a ventilated anti-radiation protection, it will be
sufficient to respect a distance of 40 cm.
Outside the radiation field
The structural elements built with fuelling
materials or which present fuelling components
and furniture, must be positioned at a minimum
distance of 5 cm from the hearths covering.
In such air space, the air present in the room
must be able to circulate freely. No heat
accumulation must be created.
Electric lines
There must be no electric lines in the walls and
the ceilings, including the hearth embedding
area.
Movement inlets
Two rings (A) have been prearranged to facilitate
the conveying of the monobloc on the sides of
the hearth.Insert the two steel pipes provided, in
the rings.
The two tubulars will serve as inlets for the
hand conveying of the monobloc, after having
eventually lightened it by removing the entire
Ecokeram earth (about 70 kg).
A A

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cristal 76Cristal 90

Tabla de contenido