BML-S _ B/C/E0-Q _ _ _ -M4 _ _ - _ 0-KA _ _ /KA _ _-S284
Incremental Magnetic Linear Encoder
4
Installation and connection (continued)
4.3
Assembling the limit switch magnets
The front and rear limit switch magnets must always be
assembled on the right side of the sensor head.
If the emergency stopping distance exceeds the length of
a limit switch magnet, several magnets may be lined up.
The limit switch sensor becomes active once it moves into
the magnetic area of the limit switch magnet.
Limit switch magnets in housing
► Fasten the front limit switch magnet with the nose to
the rear and the rear limit switch magnet with the nose
to the front.
Rear limit
switch magnet
Emergency stopping
Traveling distance (measuring range)
distance
Limit switch magnets without housing
► For the front limit switch magnet mount the groove to
the right of the centre and to the left of the center for
the rear limit switch magnet.
Rear limit switch magnets:
Groove left of center
Sensor head
Limit switch magnets bonded to the
machine
Magnetic tape
Limit switch magnets are not designed for
detecting positions. Use the reference points to
detect positions!
10
english
Front limit
switch magnet
Emergency stopping
distance
Front limit switch magnets:
Groove right of center
Comply with the distance from the
installation surfaces
4.4
Electrical connection
Note the information on shielding and cable
routing on page 12.
1.1.1
Connector S284/cable connection
BML-S...B/E0-Q53_-M400.../
BML-S1C0-Q53_-M400... (HTL output)
S284
Cable
Signal Description
Pin
color
1
WH White
+A
3
GN
Green
+B
7
BU
Blue
GND
8
RD
Red
UB
Shield
TR
Trans-
PE
parent
Pins 2, 4, 5, 6, 9, 10, 11, and 12 are not assigned.
Tab. 4-1:
BML-S...B/E0-Q53.../BML-S1C0-Q53... pin assignment
BML-S...B/E0-Q53_-M400.../
BML-S1C0-Q53_-M400...: 4-wire cable,
shielded.
All others: 12-wire cable, shielded.
12-wire cable with sense lines (measuring lines) to avoid
voltage drops in the supply.
2
11 3
10
4
1
5
9
12
6
8
7
Fig. 4-2:
M12 plug pin assignment (view on pin side)
Rectangular signal
Rectangular signal,
90° phase-delayed to
A
Sensor head ground
(0 V)
Supply voltage
10 to 30 V DC
PH shield PE
connector housing/