Pressure Testing; Conversion From Natural Gas To Lpg - Proline PGH4FGL-FR Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Set the gas tap to the MIN flame position then turn the control knob from
several times. If the flame is unstable or is extinguished follow the procedure
below.
Procedure:
Re ignite the burner and set to
Remove the control knob.
To adjust, use a thin bladed screwdriver (not
supplied) and turn the adjustment screw until the
flame is steady and does not extinguish, when
the knob is turned from
Repeat this procedure for all burners.

Pressure testing

Remove left hand pan support and front left burner cap and crown.
Fit manometer tube over the injector.
Turn on the burner gas supply and ignite another burner.
Turn off the burner supplies.

CONVERSION FROM NATURAL GAS TO LPG

Important
The replacement / conversion of the gas hob should only be undertaken by a
competent person.
It is important to note that this model is designed for use with natural gas but can be
converted for use with butane or propane gas providing the correct injectors are fitted.
The gas rate is adjusted to suit.
Method
Ensure that the control knobs are in the
Cut off the gas supply and disconnect the hob from the mains socket.
Remove all pan supports, burner caps, rings, crowns and control knobs.
With a 7mm box spanner (not supplied), unscrew the burner injectors and replace
them with the appropriate LPG injectors.
.
to
.
position.
11
to

Publicidad