Appendix
Anhang
Additional UL requirements
1.
Installation
For a complete safe and vault installation connect to 'high security cable'.
This product shall be installed in accordance with The Canadian Electri-
cal Code, Part 1, Safety Standard for Electrical Installations.
2.
Programming - Sensitivity
•
Remote input (terminal 7) must not be able to be activated manually.
It has to be assured that remote input is only active while functional
noise requires its activation.
•
Remote input must not be activated permanently and is limited to
60 seconds.
2.1. Sensitivity settings verified by UL for Monolithic Concrete:
Minimum thickness Maximum spacing
2.5m
8.2ft
4.0m
13.2ft
0.6m
1.98ft
5.0m
16.5ft
•
For coverage of surfaces over corners, the recommended spacing is
reduced by 75%.
2.2. Sensitivity settings verified by UL for Modular Steel Panels:
Minimum thickness Maximum spacing
1.0m
0.006m
0.25in
1.5m
2.0m
•
A detector shall be on each modular wall panel that is not continu-
ously welded.
•
For coverage of surfaces over corners, the recommended spacing is
reduced by 75%.
2.3. Sensitivity settings verified by UL for Steel Safes:
Minimum
Maximum
Placement
thickness
spacing
Body
0.006
0.25in 1.0m 3.3ft Steel 1m
m
Door
Body
0.006
0.25in 1.5m 4.9ft Steel 1.5m
m
Door
Body
0.006
0.25in 2.0m 6.6ft Steel 2m
m
Door
•
At least one detector is to be mounted on the door and at least one
detector is to be mounted on the body.
* Note: Shock sensitivity is defined as the sensitivity to single impacts on
the detector or its base. Only in USER MODE, the shock sensitivity can
be set independently of Mode and Operating radius with the help of the
ISN-SMS-W7 SensTool Software. If one of the fixed DIP setting is used,
the shock sensitivity corresponds to Mode and Operating radius as indi-
cated in the tables above.
F.01U.326.908-04
Annexe
Appendice
Mode and
Shock
operating radius
sensitivity*
Concrete 2.5m
High
Concrete
High
4m
Concrete
High
5m
Mode and
Shock
operating radius
sensitivity*
Steel
3.3ft
Low
1m
Steel
4.9ft
Mid
1.5m
Steel
6.6ft
Mid
2m
Mode and
Shock
operating ra-
sensitivity*
dius
Low
Mid
Mid
Anexo