4401
0
4402
ucSteuerArtEx
4403
uckanStat
4404
0
4405
uckanStat
4406
ucRzStState[ucknr]
4407
ucVBStat
4500
0
4501
ucknr
4600
ucVorgabe
4601
(sRampe.uc2VBkMsk
sRampe.ucVBkMsk)
4602
sRampT.ucNState
4603
sRampe.ucState
4700
0
4701
4702
4703
4704
4705
ucknr
4706
ucknr
4707
ucknr
4708
ucknr
4709
ucknr
4710
ucknr
4711
ucknr
4712
ucknr
4713
ucknr
4714
ucknr
4715
ucknr
4716
ucknr
4717
ucknr
4800
uiActTmr
4801
ucSgIdx
4802
0
4900
ucknr
5000-5999 Internal faults generated from within application (firing-rate control)
D1
D2
5000
enInterneLastSeq
5001
0
5002
0
5003
0
5004
0
5005
0
5007
0
5008
0
timeout while waiting for ???
invalid value of ucSteuerArtEx
(uckanStat & Def_VkM2_MSk) != Def_VkM2_DVAL
timeout while waiting for ???
disabled channel is moving!
invalid value of ucRzStState[ucknr]
invalid value of ucVBStatn
sRampe.uiLaufzeit == 0!
IfkM_VB() returned 0
invalid value of ucVorgabe
No VB channels can be active in VSM_NOVB
Unknown default state
invalid value of sRampe.ucState
Ramp time expired!
Transferred channel number out of the permitted range
Transferred channel number out of the permitted range
Transferred channel number out of the permitted range
Transferred channel number out of the permitted range
Transferred channel number out of the permitted range
Transferred channel number out of the permitted range
Transferred channel number out of the permitted range
Transferred channel number out of the permitted range
Transferred channel number out of the permitted range
Transferred channel number out of the permitted range
Transferred channel number out of the permitted range
Transferred channel number out of the permitted range
Transferred channel number out of the permitted range
Transferred channel number out of the permitted range
Transferred channel number out of the permitted range
Transferred channel number out of the permitted range
Transferred channel number out of the permitted range
ucErg > 0!
Parameter modification knf_uiActuatorDirX while fuel/air ratio control is active or outside
the operation modes "Burner Off" or "Fault"
Allowed scope for the channel too small to assess the maximum speed
Division by 0
invalid value of enInterneLastSeq
Ambiguous DPS+ / DPS- for load stage selection
Curve error: curve for n-staged oil or channel speed for actuators was not determined
Invalid parameter in function call
Timers for the control of the stage switching time do not fit together: Switch-ing time of
internal load < supervised time for set load
Invalid stage curve with internal load set by the stage controller
Invalid load value while adjusting the staged oil curve
Invalid stage- activation control mode
45 / 50
0006081511_201311
Description