English
12.11 Display messages
NOTE - Here follows a list of alarm messages (in addition
to those explained before) that can be displayed
and the relative machine conditions.
STANDBY: the machine is switched off (the main switch
is on "I") and the automatic switching-on/off functions
enabled (Pr. 12.7.1).
ANTI-FREEZING: the machine is switched off (the main
switch is on "I") and the function protecting boilers from
icing-up is enabled (Pr.12.7.1).
PROGRAMMED CLEANING: it is displayed when the
machine is performing the automatic cleaning of the brew
group (Pr. 12.7.1).
FILL CIRCUIT: this message is displayed if the machine
detects the lack of water in the boilers during a beverage
brewing.
After checking if there is actually water in the supply net-
work, press the button
water comes out properly from the spout (11) and from the
brew group (22). In the "COFFEE" version the water comes
out only from the brew group
PROGRAMMING: it is displayed during the machine
programming (Pr. 12.6).
REMOVE GROUNDS: it is displayed if the dump box
(16) is almost full (the machine performed the programmed
number of brewings).
More brewings can anyway be performed.
REMOVE GROUNDS: the dump
OUT OF SERVICE
box (16) is completely full (the machine performed the
programmed number of brewings).
The machine is blocked and no more brewings can be
performed until the dump box is emptied.
CLOSE DOOR: the door (15) is not properly closed.
INSERT BOX: the dump box (16) is not properly inser-
ted.
INSERT DRIP TRAY (except 2 grinder unit set-up): the
powder tray (12) is not properly in place.
INSERT GROUP: the brew group (27) is not properly
inserted.
GROUP ERROR: the brew group (27) is not properly
performing his working cycle; switch the machine off and
call the AUTHORIZED CUSTOMER SERVICE CENTER.
PUMP ERROR: one of the pumps is damaged. Switch
the machine off and call the AUTHORIZED CUSTOMER
SERVICE CENTER.
176
( ^ in the COFFEE version), until
SENSOR ERROR 01: is displayed when a temperature
sensor fails. Switch the machine off and call the AUTHO-
RIZED CUSTOMER SERVICE CENTER.
TEMPER. ERROR 01: is displayed when one of the boilers
resistance is damaged. Switch the machine off and call the
AUTHORIZED CUSTOMER SERVICE CENTER.
DESCALING: it is displayed when the machine needs a
descaling intervention, and after performing the program-
med number of brewings. Switch the machine off and call
the AUTHORIZED CUSTOMER SERVICE CENTER.
The descaling interventions are set on working cycles of
the machine, and can be programmed by the maintenance
technician.
MAINTENANCE: it is displayed when the machine needs
maintenance and after performing the programmed num-
ber of brewings. Switch the machine off and refer to the
AUTHORIZED CUSTOMER SERVICE CENTER.
The maintenance interventions are set on working cycles of
the machine, and can be programmed by the maintenance
technician.
12.12 Machine switching-off
Programmed automatic switching-off
This is possible when the function "AUTOM.SWITCHING-
ON" (Pr. 12.7.1) is enabled and the function "TIMES ON/
OFF" (Pr. 12.7.1) has been programmed .
At the programmed time the machine goes on "STAN-
DBY".
Manual switching-off
This switching-off is necessary if the function "AUTOM.
SWITCHING-ON" (Pr. 12.7.1) is not enabled.
It can be obtained by switching both the main switch (18)
and the all-pole switch on the "0" position or by discon-
necting the plug.