This manual describes the Alarm.com modules used with the SCW9055/57 models.

Introduction to the Alarm.com modules

The following introductory sections identify the Alarm.com modules and offer a brief overview as to their cap-
abilities.

LTE module TL8055LT

The LTE module enables wireless reporting of all alarms and other system events from the DSC IMPASSA
control panel using an all-digital, LTE wireless (cellular) network. The module can be used as the primary
communication path for all alarm signaling, or as a backup to a telephone connection to the central monitoring
station. The wireless alarm signaling and routing service is operated by Alarm.com. The LTE module also fea-
tures integrated support for Alarm.com's home automation solution with built- in Z- Wave capabilities. Model
TL8055LT is a single communication channel using two technologies (cellular LTE/IP) for sending alarms to
supervising station.
Note: Alarm.com's home automation solution with built-in Z-Wave capabilities is not UL/ULC evaluated.

Contact information

For additional information and support on Alarm.com modules, initial account setup, home automation, and all
other Alarm.com products and services, please visit: www.Alarm.com/dealer or contact Alarm.com technical
support at: 1-866-834-0470.

Compatibility

The TL8055LT module is compatible with DSC IMPASSA panels: SCW9055G- 433 and SCW9057G- 433
V1.3+. Note that the 9055 version does not support two-way voice communication.

Installation

Follow these guidelines during installation:
Before affixing the panel to a wall, verify the LTE signal level at the installation location. On the
l
IMPASSA panel, press and hold the 5 key for 2 seconds to view the LTE signal level. An installation loc-
ation with a sustained signal level of two or more bars is recommended.
Do not exceed the panel total output power when using panel power for the LTE module, hardwired
l
sensors, and /or sirens. Refer to the specific panel installation instructions for details. Only one Alarm.-
com LTE module can be used per IMPASSA panel.
The LTE module draws on average 100 mA during normal operation. In PowerSave mode, during or
l
immediately following an AC power failure, the module will draw only 5mA on average (10mA with an
image sensor daughterboard).
To minimize potential interference with cellular signaling, avoid mounting the panel in areas with excess-
l
ive metal or electrical wiring, such as furnaces or utility rooms.

UL/ULC installation requirements

For ULC Residential fire and burglary applications, the TL8055LT
munication channel via Cellular, or as a back-up in conjunction with the Digital Alarm Communicator Trans-
mitter (DACT). Test transmission every 24 hours is enabled on each channel.

Alarm.com LTE

- 7 -
UL/ULC
can be used as a primary com-
Alarm.com LTE