Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

LSR<n>?
LSE<n> <nrf>
LSE<n>?
SAV<n> <nrf>
RCL<n> <nrf>
RATIO <nrf>
RATIO?

System and Status Commands

*CLS
EER?
*ESE <nrf>
*ESE?
*ESR?
*IST?
*OPC
*OPC?
*PRE <nrf>
*PRE?
QER?
*RST
*SRE <nrf>
*SRE?
*STB?
*WAI
Query and clear Limit Event Status Register <n>.
The response is <nr1><rmt>. See Status Reporting section for details.
Set the value of LSE<n>, Limit Event Status Enable Register <n>, to <nrf>
Return the value of LSE<n>, Limit Event Status Enable Register <n> - response
is <nr1><rmt>
Save the current set-up of output <n> to the set-up store specified by <nrf>
where <nrf> can be 0-9.
Recall a set up for output <n> from the set-up store specified by <nrf> where
<nrf> can be 0-9.
Set the ratio of output 2 (slave) to output 1 (master) in tracking mode to <nrf>,
where <nrf> is the ratio in percent (0 to 100). No action on this instrument.
Query the ratio of output 2 (slave) to output 1 (master) in tracking mode. The
response is <nrf>, where <nrf> is the ratio in percent (0 to 100). No action on this
instrument.
Clear Status. Clears the Status structure. This indirectly clears the Status Byte
Register.
Query and clear Execution Error Register. The response format is nr1<rmt>.
Set the Standard Event Status Enable Register to the value of <nrf>
Returns the value in the Standard Event Status Enable Register in <nr1> numeric
format. The syntax of the response is <nr1><rmt>
Returns the value in the Standard Event Status Register in <nr1> numeric format.
The register is then cleared. The response is <nr1><rmt>. See Status Reporting
section for details.
Returns ist local message as defined by IEEE Std. 488.2. The syntax of the
response is 0<rmt>, if the local message is false, or 1<rmt>, if the local message
is true.
Sets the Operation Complete bit (bit 0) in the Standard Event Status Register.
This will happen immediately the command is executed because of the
sequential nature of all operations.
Query Operation Complete status. The response is always 1<rmt> and will be
available immediately the command is executed because all commands are
sequential.
Set the Parallel Poll Enable Register to the value <nrf>.
Returns the value in the Parallel Poll Enable Register in <nr1> numeric format.
The syntax of the response is <nr1><rmt>
Query and clear Query Error Register. The response format is nr1<rmt>
Resets the instrument to the remote control default settings with the exception of
all remote interface settings, stored set-ups, Vmin/Vmax values and Output state
at power-on setting (see Remote Operation Defaults paragraph in the Remote
Interface Operation section)
Set the Service Request Enable Register to <nrf>.
Returns the value of the Service Request Enable Register in <nr1> numeric
format. The syntax of the response is<nr1><rmt>
Returns the value of the Status Byte Register in <nr1> numeric format. The
syntax of the response is<nr1><rmt>
Wait for Operation Complete true. As all commands are completely executed
before the next is started this command takes no additional action.
35

Publicidad

Tabla de contenido
loading

Productos relacionados para Metek Sorensen XEL serie

Este manual también es adecuado para:

Sorensen xel 120Sorensen xel 250

Tabla de contenido