The answers are listed below in summary form, for further details see the other pages of this document.
1) What do I need to prepare in order to install the boiler- replace?
Smoke outlet that is at least 80 mm in diameter.
Connected to the outside air intake (see page 9).
¾" G outlet and inlet tting.
¾" G drains connection for overpressure valve.
¾" G load tting.
A certi ed electrical connection with a thermal magnetothermic switch 230V +/- 10% 50 Hz.
(assess the division of primary and secondary circuits).
2) Can the boiler- replace work without water?
NO. Using the boiler- replace without water will damage it.
3) Can I connect the inlet and outlet of the boiler- replace directly to a radiator?
NO, just like other boilers, it must be connected to a collector from which the water is then distributed to the radiators.
4) Do boiler- replace also supply hot sanitary water?
It is possible to produce hot sanitary water evaluating the power of the boiler- replace and the water plant.
5) Can I discharge the smoke from the boiler- replace along the wall?
NO, a discharge which is conform with standards (UNI 10683) must reach the ridge of the roof, and in any case proper functio-
ning requires a vertical stroke of at least 1.5 meters; avoiding that in case of power outage or wind, a slight amount of smoke
forms in the installation environment.
6) Do I need an air inlet in the room where it is installed?
Yes, to replenish the air used by the boiler- replace for combustion. The smoke extractor draws the air from the room into the
combustion chamber.
7) What settings are required on the boiler- replace display?
The desired water temperature; the boiler- replace will then adjust the power accordingly to obtain or maintain this. For small sy-
stems, a mode can be set that ignites and shuts down the boiler- replace accordingly, as the water temperature is reached. (contact
DEALER for initial start up)
8) How often do I need to clean the combustion chamber?
Before you ignite the boiler- replace, every time, when it is off and cold. AFTER HAVING SWAB-CLEANED THE EXHANGE
PIPES using the metal chimney ue cleaning levers. (see page 39).
9) Can I burn other fuel apart from pellets?
NO. The boiler- replace has been designed to burn wood pellets that are 6 mm in diameter. Any other material can damage it.