Adjustment; Control Panel; Switching The Machine On; Program Selection And Variable Setting - Minipack-Torre Tunnel 50 Digit Instrucciones Para La Instalación, Uso Y Mantenimento

Ocultar thumbs Ver también para Tunnel 50 Digit:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 51
Chapter 6. Machine adjustment and setting up

6.2. Adjustment

6.2.1. Control panel

The machine is fitted with a control panel, from which all
programming and operation functions can be set.
1.
Main switch
2.
Variables selection switch
3.
Button "DECREASE". Reduces set function values
4.
Button "INCREASE". Increases set function values
5.
START button
6.
STOP button
7.
Temperature display
8.
Belt display
9.
EMERGENCY pushbutton. If pressed, it immediately
stops the machine in case of immediate danger.

6.2.2. Switching the machine on

Turn the main switch (1) into pos. 1.
The display (8) turns on and the number of the currently selected program will appear.
Press START button (5).
Before using the machine, wait until the adjusting temperature is reached. This is signalled by the extinction of the
warning light (A).
Press button (6) to display the active programme number.

6.2.3. Program selection and variable setting

The machine is equipped with 9 selectionable programs (P1 ÷ P9).
Each program is composed by 2 variables which can be modified.
Variable
1. Tunnel temperature
2. Tunnel belt speed
Push button (3) and (4) to select the number of the program.
Press button (2) to access the programme on the display.
Through button (2) it is possible to look through the variables of the selected program, while through buttons (3) and (4)
the memorized values can be modified. To validate modifications, press button (2).

6.2.4. Switching machine off

Press STOP button (6).
Press this button to provide for the timed power off of the tunnel (resistances are powered off, the tape turns at the
minimum speed, but the fan wheel continues to work for about 3-4 minutes so as to enable the tunnel to cool down).
When the fan wheel and tape stop, turn main switch (1) and set it to 0.
Field
Field features
000 ÷ 230.
Values expressed in °C.
00 ÷ 99.
Values expressed in percentage:
00: minimum speed; 99: maximum speed
20
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido