UK
Trouble Shooting
Fault
Does not heat
Slow to Heat
Error message E01 is displayed
LCD Display does not switch on
Technical Specification
Model
Voltage
Power
DM868
230v 50hz
1500w
Electrical Wiring
This appliance is supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as standard.
The plug is to be connected to a suitable mains socket.
This appliance is wired as follows:
•
Live wire (coloured brown) to terminal marked L
•
Neutral wire (coloured blue) to terminal marked N
•
Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required
they must be readily accessible.
Probable Cause
No power
Power switch is set to OFF
Thermal Protector has activated
Unit needs Descaling
Unit is not sitting in the water
Water level is too low.
Power switch is set to OFF
Thermal Protector has activated
Dimensions
Current
h x w x d mm
6.5A
320 x 145 x 130
Action
Make sure the machine is
plugged in correctly
Set the power switch to ON
Reset Thermal Protector
Descale unit
Make sure the unit is sitting in the
water and that the water level is
between the MIN and MAX line.
Add water, make sure the water
level is between the MIN and
MAX line.
Set the power switch to ON
Reset Thermal Protector
Weight
(kg)
2.35kg
6