6.2.3 Single wall pipe and outside air intake
In this case the combustion air is taken directly
from outside, from the back of the stove.
• Remove the back panel of the stove (A)
• Disconnect the flexible combustion air hose (B)
at the top and bottom.
• Insert the aesthetic ring support (C) (supplied
with and placed inside the combustion cham-
ber during transport).
• Connect the flue gas pipe (D) (Fig. 16)
D
B
C
A
52
B
Fig. 16
• Remove the elbow (D)
• Remove the preform (E) on the back panel (A)
and insert the flexible hose (B) to connect it to
an outside air intake (Fig. 17).
• Tighten the hose (B) with the previously loos-
ened metal hose clamp (F)
• Refit the back panel (A)
A
E
B
D
Fig. 17