Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 34
AK1001B
AK1002B
4
grey water pump. All previous components of the switching system can be ignored or discarded.
For further information please refer to the Installation Instruction Section 8-15.

8. WARNINGS

Failure to fuse and connect the sensor according to these instructions will void the product
warranty. Incorrect wiring will cause failure, permanent damage or serious injury.
Connect in-line fuse of the amperage specified for your pump model.
Proper voltage range is 10.5 to 28.8 volts DC.
The connected pump may draw up to a maximum of 20 amps.
Please note that incorrect installation or use of non original Whale parts may invalidate
the warranty.
Contact the technical helpline (Whale +44 (0)2891 270531) if require further advice.
9. ASSEMBLY
Please follow the step by step assembly instructions laid out in Figures 1 to 4 before attempting
to fit your service kit to MKII or III models of the Whale grey waste tanks. (For reference of which
model of tank you have please refer to Figures 5 to 11. All tanks shown are 8ltr (2.2 US gals)
models, but the same instructions apply to 16ltr (4.4 US gals) tanks). For AK1002B with double
switch, the same assembly steps apply.
For MKI models pull the brown and black wires completely through the 2 wire grommet on the
clear lid and discard this lid. PLEASE NOTE: The lid included in this kit is not a replacement for
the white lid which has been discontinued.
Fig. 1
Munster Simms Engineering Ltd., 2 Enterprise Road, Bangor, Co. Down, N. Ireland, BT19 7TA
GREY WASTE TANK
SERVICE KIT
Fig. 2
Tel: +44 (0)28 9127 0531
Web:www.whalepumps.com Email: info@whalepumps.com
Fig. 3
Fig. 4

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ak1002b

Tabla de contenido