Quick Parameter Reference, Faults and Alarms
Param.
Description
P0263 DI1 Function
P0264 DI2 Function
P0265 DI3 Function
P0266 DI4 Function
P0267 DI5 Function
P0268 DI6 Function
P0269 DI7 Function
P0270 DI8 Function
10 | CFW700
Adjustable Range
0 = Not Used
1 = Run/Stop
2 = General Enable
3 = Fast Stop
4 = FWD/REV
5 = LOC/REM
6 = JOG
7 = SoftPLC
8 = Ramp 2
9 = Speed/Torque
10 = JOG+
11 = JOG-
12 = No External Alarm
13 = No External Fault
14 = Reset
15 = Flying Start Disabling
16 = DC Link Regulator
17 = Program. Disabling
18 = Load User 1
19 = Load User 2
20 = Application Function 1
21 = Application Function 2
12 = Application Function 3
23 = Application Function 4
24 = Application Function 5
25 = Application Function 6
26 = Application Function 7
27 = Application Function 8
28 = Application Function 9
29 = Application Function
10
30 = Application Function
11
31 = Application Function
12
Refer to the P0263 options
Refer to the P0263 options
Refer to the P0263 options
Refer to the P0263 options
Refer to the P0263 options
Refer to the P0263 options
Refer to the P0263 options
Factory
User
Prop.
Setting
Setting
1
cfg
4
cfg
0
cfg
0
cfg
6
cfg
8
cfg
0
cfg
0
cfg
Groups Pag.
I/O
13-10
I/O
13-10
I/O
13-10
I/O
13-10
I/O
13-10
I/O
13-10
I/O
13-10
I/O
13-10