Operation
1
Completing a DC Voltage Measurement
Connect the red test lead (G) to the
VΩmA jack (F) and the black test lead
(H) to the COM jack (E).
Set the rotary switch (C) to the
desired DCV position.
NOTE: When the value to be
measured is unknown before a
measurement, set the range
selector at the highest position.
Connect the red and black test leads
(G and H) across the source or load
being measured.
Read the voltage value on the LCD
display (A) along with the polarity of
the red lead (G) connection.
2
Completing a DC Current Measurement
Connect the red test lead (G) to the
VΩΩ m A jack (F) and the black test lead
(H) to the COM jack(E). For measurements
between 200mA and 10A, insert the
red test lead (H) into the 10A jack (D).
Set the rotary switch (C) to the desired
DCA position.
Open the circuit in which the current
is to be measured, and connect the
red and black test leads (G and H) in
series with the circuit.
Read current value on the LCD display
(A) along with the polarity of the red
lead (G) connection.
E
D
H
CATII
HOMEDEPOT.COM
7
Please contact 1-877-527-0313 for further assistance.
Operation (Continued)
3
Completing an AC Voltage Measurement
Connect the red test lead (G) to the
V Ω m A jack (F) and the black test lead
Ω
(H) to the COM jack (E).
Set the rotary switch (C) to the
desired ACV position.
Connect the red and black test leads
(G and H) across the source or load
being measured.
Read the voltage value on the
LCD display (A).
4
Completing a Resistance Measurement
WARNING: If the resistance being
measured is connected to a circuit,
turn off power and discharge all
capacitors before applying the
A
test leads.
Connect the red test lead (G) to the
V Ω m A jack (F) and the black test lead
Ω
(H) to the COM jack (E).
C
Set the rotary switch (C) to the desired Ω
F
(omega) range position.
Connect the red and black test leads
G
(G and H) across the resistor to be
measured.
Read the resistance value on the LCD
display (A).
E
F
H
CATII
E
H
CATII
8
A
C
G
A
C
F
G