Error Code
Err 14
EN
Err 15
Err 16
Err 18
8. Technical Data
8.1
Silent V4
Permissible mains voltage / mains frequency:
Power consumption *):
Electrical power of suction turbine *):
Mains input fuse ***):
max. connection pressure:
min. connection pressure:
LpA **) (at max. volume flow):
Number of suction hoses:
Volume flow, max.:
Vacuum pressure, max.:
Fine particle filter:
- Filter surface area, approx.:
- FIlterquality:
Fill level dust drawer, approx.:
Dimensions (width x height x depth):
Weight (empty), approx.:
Ø Suction fittings:
- Internal:
- External:
*)
Nominal voltage power / Nominal frequency
**)
Sound pressure levels according to EN ISO 11202
***) 2 x 10 A (T) for units produced until March 2018
Cause / Meaning
• Error made when adjusting the on / off
threshold.
• The difference between stand-by power and
operating current is too low.
• Quattro Control-Box without power.
• Vacuum power for cleaning is too low.
• Remote control distribution box not
connected.
• Distribution box faulty.
Nominal voltage
Corrective Action
• Cancel the on / off threshold setting using the menu
key (30, Fig. 2) and continue as described in section
5.6.4.
• Set the on / off threshold with a higher rpm on the
handpiece.
• Operate the suction channel manually.
• Check the power supply for the Quattro Control-Box
(See section 5.6.1).
• Make sure the pinch valve in the suction channel is
not blocked and that the membrane in the pinch valve
is not defect.
• Make sure the dust drawer is in its correct position.
• Check remote control distribution box connection. cf.
also instructions for 2933 0420, remote control starter
kit.
• Send distribution box in for repair.
220 - 240 V +/-10 %
8 bar [116 psi]
4.5 bar [65 psi]
4000 l/min [2.35 ft³/s]
11 kPa [1.6 psi]
1.8 m² [70.87 inch]
Class M according to EN 60335-2-69
12 l [3.17 US gal]
350 x 750 x 590 mm /
[13.78 x 29.53 x 23.23 inch]
45 kg [99.36 lbs]
38 mm [1.50 inch]
45 mm [1.77 inch]
- 24 -
230 V
50 / 60 Hz
7.5 A
1400 W
2 x 12 A (T)
63 dB(A)
4