- Check that the water collection tray is in good working conditions (only in some models).
- Check that the drainage pipe in the chamber is not blocked.
- Check that the condenser circuit is not blocked with dust. If dirty, call the Technical Service for cleaning.
- Check that the evaporator fan grilles are not blocked by bits of food.
3.2 NON-USE FOR LONG PERIODS OF TIME
- Disconnect the appliance with the ON / OFF button if it has this option.
- Disconnect the connection cable.
- Empty and clean inside.
- Leave the door with an open gap for air circulation and to prevent mould from forming.
3.3 GENERAL MACHINE CHECKS
In the event of having to call for the technician, you can check the machine before ringing. In some cases the
operating faults that can occur are caused by something simple that the users themselves can solve.
The following are examples:
a) The Cooler does not work
Check that power reaches the Cooler, looking to see that the main switch is in the ON position
b)
Temperature too low
Check that there are no heat sources nearby.
Check that the room temperature is not above +30 ºC, which is the machine's maximum operating
temperature.
Check that the goods load is perfectly positioned and does not obstruct the outlets of the inner fan,
and that the time it has been inside is sufficient to cool the products.
Check that the condenser is clean: You must bear in mind that the cleaner the refrigerator is the
greater the energy saving, particularly the condenser's ribbing. The frequency of this cleaning will be
determined by the characteristics of the premises. If it is dirty, call the technical support service to
clean it.
Check that the doors close properly.
c)
In the event of strange or excessive noise
Check the unit's levelling and that the doors close properly.
Check that there are no objects touching any of the cooler's moving components.
Check that the screws (at least the visible ones) are correctly tightened.
3.4 SPECIAL MAINTENANCE
(Authorised technical staff)
Condenser cleaning: When cleaning, be careful not to bend the condenser aluminium ribs, as on the
contrary the air will not come through and will not condense, causing serious damage to the
appliance and its repair guarantee will be made void.
Check that the premise's temperature does not exceed that indicated for your Cooler.
The guarantee will be made void if there is insufficient ventilation.
Check that the doors close properly.
Do not disassemble the mobile components guards without first having turned the appliance off.
Use gloves before accessing the area of the condenser unit, given the existence of high temperatures
of some components, with the resulting risk of burns.
If the power cable is damaged, it should be replaced by authorised technical staff to prevent risks.
It if is replaced, the earth pin must be positioned again.
If you need to change a cable, you must never use a smaller section.
If it is necessary to disassemble the inner lid of the electrical installation, it is extremely important to
leave it exactly as it was when reassembling it.
3.5 TESTING AND GUARANTEE
The cooler has been tested the outcome of which has been satisfactory after the tests established for its
production.
The supplier may ask for the faulty part to be returned for analysis and statistics.
The company will correct any possible errors or faults as long as the machine has been used according to
the manual's indications.
IN THE EVENT OF PART REPAIR OR REPLACEMENT, ALWAYS SEND THE APPLIANCE'S CODE AND
REGISTRATION NUMBER, WHICH ARE ON THE NAME PLATE.
31