FUNCTIONING OF CONTROL ACCESSORIES in NORMAL MODE (DIP6 OFF)
K BUTTON
STOP
CLOSE
+
OPEN 1
LSC
LSO
LSSC
LSSO
TIMER
OPEN1 BUTTON (COM - OPEN1)
The OPEN1 button performs the open command, regardless the position of
the boom arm. If the OPEN1 button is pressed during the closing, the boom
arm stops and will reverse the movement in opening.
In PARK MODE (DIP6 ON), if there is a vehicle at the entry (see scheme
4) and the TLC contact is closed, the OPEN1 command opens the barrier.
Otherwise, if the TLC contact is open the OPEN1 command is disabled.
CLOCK FUNCTION
The Clock Function permits to keep the boom arm opened even if, for
example, the Automatic Closing is enabled (DIP3 ON) or somebody
commands the barrier closing. It is useful during rush hour, when traffic is
heavy and the flow is low (e.g. entrance/exit of employees, emergencies
in residential areas or car parks) and it's necessary to keep the boom arm
opened.
CLOCK FUNCTION APPLICATION
It can be done by connecting a switch and/or a daily/weekly timer either
in parallel to the OPEN1 button or instead of the OPEN1 button. When
the control board receives this command, the boom arm will open and by
keeping this contact closed for all the time of the boom arm opening, the
Clock Function is automatically activated.
In fact, once reached the open position, the barrier will remain opened and
all of the control board features are blocked. Only when the OPEN1 button
is released, the control board functions are re-activated and the boom arm
will close immediately.
CLOSE BUTTON (COM - CLOSE)
The CLOSE button performs the close command, regardless the position
of the boom arm.
STEP BY STEP or AUTOMATIC COMMANDS (COM - K BUTT)
DIP5 - OFF => The K BUTT performs the cyclic command open-stop-close-
stop-open etc.
DIP5 - ON => The K BUTT performs:
- the open command, if pressed with the barrier completely
closed
AERIAL
+
+
BUZZER
LED
R=2K2
-
_
_
12 Vdc max 0,5A for ACCESSORY SUPPLY
+
_
12 Vdc max 0,5A for AUTOTEST EDGE
+
EN
STANDARD OPERATION
DIP 6 OFF
COAX
NC
NO
COM
S
D-
D
+
MAGNETIC LOOP
- the close command, if pressed with the barrier completely
opened
- no effect, if pressed during the barrier opening
- the boom arm re-open, if pressed while the barrier is
closing
REMOTE CONTROL
DIP4 - OFF => The REMOTE CONTROL performs the cyclic command
open-stop-close-stop-open etc.
DIP4 - ON => The REMOTE CONTROL performs:
- the open command, if pressed with the barrier completely
closed
- the close command, if pressed with the barrier completely
opened
- no effect, if pressed during the barrier opening
- the boom arm re-open, if pressed while the barrier is
closing
AUTOMATIC CLOSING (DIP3 ON)
The Automatic Closing from the complete open position can be enabled
turning ON the DIP3. The maximum time that can be programmed is 5
minutes (see Point D).
ENTRY
S
D-
D
TO EXIT
3