Operation; Disassembly And Repair; Maintenance And Care - Festo ZSB-1/8-B Instrucciones De Utilizacion

Ocultar thumbs Ver también para ZSB-1/8-B:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ZSB-1/8-B
7

Operation

Checking the functional reliability:
• Implement a functional test of the product every month (è chapter 6.1).
• Keep a record of the functional tests in your documents.
If the media temperature is below +1 °C:
• Use suitable compressed air (è chapter 12.2). Doing this will prevent the condensed water from
freezing.
8

Disassembly and repair

• Exhaust the complete system and the product.
Warning
Danger from impact. Pressurised hoses can move uncontrollably when disassembling
the product and cause serious injury.
• Exhaust the complete system and the product prior to disassembly.
• Disassemble the product from the system.
• The product should only be repaired by Festo. Send the product to Festo's repair service
(è www.festo.com).
9

Maintenance and care

Maintenance
• Check the function of the product every month (è chapter 6.1)
• Replace the product after 1,000,000 switching cycles (è chapter 12.1 with sample calculation).
Cleaning:
1. Exhaust the complete system and the product.
2. Disassemble the product from the system as described in chapter 8.
3. Unscrew the filter element 5. Do not lose the seals when doing this.
4. Only clean the components of the product by using cleaning agents in accordance with Tab. 2:
5. Re-tighten the screw with filter element 5 (max. tightening torque 4 Nm).
Component
Housing
– Screw with filter element 5
– Silencer
Tab. 2
18
Cleaning agents
Water (max. +60 °C)
– Compressed air
– Water (max. +60 °C)
– Petroleum ether
Cleaning interval
As needed
– every six months or
– after 100,000 switching
cycles
Festo – ZSB-1/8-B – 1603a English

Publicidad

Tabla de contenido
loading