System Components

Section 2
Please review the S-Drive components and insure that you have all the parts and are familiar with their
names. Be sure to inspect all components Goulds Pumps supplies for shipping damage.
S-Drive Variable Speed Controller:
1. S-Drive Controller
2. Pressure Transducer with Cable
3. Conduit Plate Caps
Warning
DO NOT power the unit or run the pump until all electrical and plumbing connec-
WARNING
tions, especially the pressure sensor connection, are completed. The pump should
Hazardous
voltage
not be run dry. All electrical work must be performed by a qualified technician. Al-
ways follow the National Electrical Code (NEC), or the Canadian Electrical Code (CEC)
CAUTION
as well as all local, state and provincial codes. Code questions should be directed to
Hazardous
Pressure
your local electrical inspector or code enforcement agency. Failure to follow electrical
codes and OSHA safety standards may result in personal injury or equipment damage. Failure to
follow manufacturer's installation instructions may result in electrical shock, fire hazard,
personal injury, death, damage to equipment, unsatisfactory performance and may void
manufacturer's warranty.
Controller Product Code Information
SPD Y XXXX
F
F = WITH OUTPUT FILTER
BLANK = NO OUTPUT FILTER
4 DIGITS FOR HP
5 HP = 0050
7.5 HP = 0075
10 HP = 0100
15 HP = 0150
20 HP = 0200
25 HP = 0250
30 HP = 0300
1 DIGIT FOR INPUT VOLTAGE
230 VOLT = 2
460 VOLT = 4
575 VOLT = 5
SERIES
4