Technical Data - Grohe KENSINGTON 20 124 Manual De Instrucciones

Ocultar thumbs Ver también para KENSINGTON 20 124:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Application
Operation is possible in conjunction with:
- Pressurized storage heaters
- Thermally controlled instantaneous heaters
- Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters
(displacement water heaters) is not possible.

Technical data

• Max. flow
20 124 00A
20 124 000
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit with pressure reducing valves
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
- thermal disinfection possible
• Water connection
Note
Major pressure differences between cold and hot water supply
should be avoided.
Installation
See dimensional drawing on page 1.
Flush pipes thoroughly!
Side valves, see figs. [1] and [2].
• Valve with a groove on the top edge of the cartridge (A) and
in addition marked with COLD should be mounted on the
right (cold water) side.
• Valve without a groove on the top edge of the cartridge (A)
and in addition marked with HOT should be mounted on the
left (hot water) side.
1. Screw the mounting set (B) to the bottom of the thread of the
side valve (C).
Make sure that the rubber washer (B1) is on the top of the
fiber washer (B2).
2. Insert the side valve (C) through the basin hole from below.
3. Place the escutcheon O-ring (D1) on the basin and screw
down the escutcheon (D) until it stops.
4. Screw the cap (E) down to the escutcheon (D).
5. Tighten the mounting set (B) from below to secure the valve.
6. Close the cartridges (clockwise for the hot side and counter-
clockwise for the cold side).
Mount lever (18 087) or handle (18 086), sold separately,
see fig. [1].
1. Slide ring (F2) on lever (F) or handle (G).
2. Push on lever (F) or handle (G) and tighten with set
screw (F1).
3. Screw the ring (F2) into the cap (E) until tight.
Hand tighten only!
It is recommended that the lever (F) be installed so they point
away from the spout when in the off position.
3
English
4.5 L/min or 1.2 gpm/60 psi
5.7 L/min or 1.5 gpm/60 psi
7.25 psi
14.5 - 72.5 psi
145 psi
232 psi
158 °F
cold - Right hand
hot - Left hand
Spout, see figs. [2] to [4].
1. Place the O-ring (I) and the escutcheon (H1) on the basin,
see fig. [2].
2. Insert the spout (H) through the escutcheon (H1) and basin.
3. Place the gasket (J) against the bottom of the basin and
fasten with the flange (K) and nut (K1). Tighten nut (K1) with
a 13mm socket wrench.
4. Connect flexible hoses (L) to the side valves, see figs. [3]
and [4].
Mount lift rod and pop-up drain, see figs. [3] and [5].
1. Insert the lift rod (M) through the spout and screw on the
lower lift rod (N), see fig. [3].
The connector is at the lower lift rod (N).
For 18 086 VP0 see also fig. [5].
2. Fit pop-up drain, see page 6.
Ensure that flange of pop-up drain is sealed.
Connect wideset
Connect the side valves to the water supply. Insure the
supplied washers are used for all connections.
The cold water supply should be connected on the right side
valve (marked COLD) and the hot water supply to the left valve
(marked HOT).
Open cold and hot water supply and check connections
for leakage!
Maintenance
Inspect and clean all parts, replace as necessary and grease
with special grease.
Shut off cold and hot water supply.
I. Ceramic cartridge, see fig. [6].
1. Unscrew ring (F2) and remove set screw (F1).
2. Pull off lever (F) or handle (G) and unscrew cap (E).
3. Unscrew the ceramic cartridge (A) using a 17mm wrench.
4. Change complete ceramic cartridge (A) or O-ring (A1).
Observe the different replacement part numbers of the
cartridges, see page 6.
II. Strainer, see page 6.
Unscrew and clean strainer (13 990).
Assemble in reverse order.
Replacement parts, see page 6 ( * = special accessories).
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement.
4

Publicidad

Tabla de contenido
loading

Tabla de contenido