MaINTENaNCE
warNINg: Always stop the water supply and unplug or
disconnect all appliances in the pond from the electrical
supply while the equipment is being installed, repaired,
maintained or handled. Never yank the cord and never lift
the appliance by the cable.
It is recommended that you:
• Make sure that internal parts of the appliance are dry before,
during and after the maintenance operations.
• Check that all the components are present and have been
reassembled in the correct way; if in doubt consult your local
dealer for a replacement of the defective component.
• Check that there are no leaks inside the appliance before
connecting it to the electrical supply after maintenance.
Lubrication is not required on the air pump or any of its parts.
Remove dust and grime from the outer shell with a soft,
damp cloth. Do not immerse the air pump in water. Regular
maintenance to the air pump is essential in order to maintain
a good level of output and pressure; change the spare parts
regularly. When not in use, store the air pump in a dry and dust
free area. In order for the air pump to perform at its capacity, it
should run for a minimum of 20 minutes every 2 ~ 3 days.
rEMoVINg ThE aIr PUMP:
Whenever the air pump must be shut off and removed from the
aeration system, always take off the air line before the air pump
is unplugged. This will prevent water from siphoning back into
the air pump. If the air line cannot be removed before unplugging
the power cord, raise the air pump above the water level.
FILTEr MEDIa:
The integrated air filter requires periodic cleaning.
Pt1620
To clean the filter media:
1. Remove the air filter cover located at the back of the filter.
(Fig 7).
2. Extract the filter media from the air pump (Fig 8) and rinse
thoroughly with cold water and let air dry.
3. Replace the filter media into the filter cavity.
4. Replace the filter cover and snap closed.
Pt1624
To clean the filter media:
1. Remove the air filter cover located at the top of the filter (Fig 9).
2. Extract the filter media from the air pump (Fig 10) and rinse
thoroughly with cold water and let air dry.
3. Replace the filter media into the filter cavity.
4. Replace the filter cover and snap closed.
7
aIr SToNE & aIr LINE:
The air system should be periodically checked and cleaned.
• Air lines should be carefully inspected whenever standard
pond maintenance is performed. Adjust, or if required, replace
all sections which are pinched, kinked, or otherwise damaged.
• All attached air-driven pond accessories should be regularly
maintained. Algae growths should be removed from moving
parts and kept as clean as possible. Internal air tubes should
be cleaned.
• Air stones should be kept clean and free of debris or algae
build-up. The ideal situation is to replace them every month.
Clogged air stones and air-driven pond accessories will lead
to low air pressure output and also reduce the life of the
8
diaphragms.
TroUbLE ShooTINg TIPS:
1. if the air pump fails to produce air, check the following:
A. Ensure that the air pump is plugged in.
B. Ensure that there are no blockages or kinks in the air hose
assembly and that all valves allow air passage. If no air is
produced by the air stone, remove the air line from the air
pump and ensure that air is being produced.
C. If the air pump produces no output, the most common
problem encountered with any air pump is a ripped or
weakened diaphragm. Any opening in the diaphragm will
make it impossible for the air pump to produce air for aeration
purposes. For service please contact the customer service
department listed on the back cover of this maintenance guide.
To rEgISTEr yoUr warraNTy oN LINE or For MorE INForMaTIoN oN ThIS aND oThEr ProDUCTS
go To www.hagen.com
warraNTy
– Laguna Air Pumps PT1620 & 1624 are warranted for defects in material or workmanship for a period of two (2)
years from date of purchase. This warranty is valid only under normal operating conditions for which the Air Pump is intended.
This warranty does not apply to any unit that has been subjected to misuse, negligence, tampering, accidental damage or damage
due to faulty packaging or mishandling in transit. This warranty does not cover normal wear of parts and does not apply to any
unit that has been used for commercial purposes. This warranty is limited to the Air Pump unit only. This warranty does not
cover rubber parts such as gaskets, seals, dampeners, etc. No liability is assumed with respect to loss or damage to livestock or
9
personal property irrespective of the cause thereof. This warranty does not affect your statutory rights. This warranty does not
cover damage or defects caused by or resulting from damages from shipping or repairs, service or alterations to the product or
any of its parts, which have been performed by a repair person not authorized by Rolf. C. Hagen Inc. The replacement items are
not covered by this warranty.
rECyCLINg
this item bears the selective sorting symbol for waste electronic and electrical equipment (WEEE).
this means that the product must be handled pursuant to European Directive 2002/96/EC in order to be recycled or
dismantled to minimize its impact on the environment. For further information please contact your local or regional
Authorities. Electronic products not included in the selective sorting process are potentially dangerous for the
environment and human health due to the presence of hazardous substances.
10
2. Winter
A. During the winter months, damp air can condense onto the
inside wall of the hose and freeze. This can eventually cause
the hose to block completely; remember to check the airlines
frequently during periods of freezing temperatures.
3. to prevent back-siphoning when removing the air stone
from the pond, do the following:
A. Ensure a check valve has been installed (see installation).
B. Leave the air pump running while you disconnect the tubing
from the air pump.
C. Disconnect the tubing and put this end of the tubing in
the pond.
D. The air stone can now be safely removed from the pond.